Adaptec 2251300-R User Guide - Page 8

Installing on OpenServer and UnixWare, Installing on Solaris, Enter

Page 8 highlights

Chapter 1: Getting Started with the Command Line Utility ● 8 2 From the command prompt type load cdrom, then press Enter. From the command prompt, type: xx_yy_zz:\netware\manager\install where xx is the product CD, yy is the version number, and zz is the release number. For example: adptcd_v2_01 The installation program starts. 3 Follow the on-screen instructions to complete the installation. Installing on OpenServer and UnixWare To install ARCCONF on OpenServer and UnixWare systems or HRCONF on OpenServer: 1 Insert the Adaptec Storage Manager installation CD in the CD drive. 2 Mount the Adaptec Storage Manager installation CD: mount -r -F cdfs /dev/cdrom/cdromdevicefile /mnt where cdromdevicefile is the device file, for example, c0b0t010, for the CD block device. To determine the actual filename, look in the /dev/cdrom directory. 3 Use pkgadd to install Adaptec Storage Manager: pkgadd -d /mnt/unixware/manager/RaidMan.ds (for UnixWare) pkgadd -d /mnt/openserv6/manager/RaidMan.ds (for OpenServer 6) 4 Follow the instructions on the screen to complete the installation. 5 Unmount the CD drive: umount /mnt Installing on Solaris Note: HRCONF is not supported by systems running Solaris. To install ARCCONF on Solaris systems: 1 Insert the Adaptec Storage Manager Installation CD. The CD mounts automatically. (If it doesn't, manually mount the CD using a command similar to the one shown below. Refer to your operating system documentation for detailed instructions.) mount -F hsfs -o ro/dev/dsk/c1t0d0s2/mnt 2 Install Adaptec Storage Manager: pkgadd -d//solaris/manager/StorMan.ds 3 Follow the on-screen instructions to complete the installation. Eject or unmount the Adaptec Storage Manager Installation CD. Refer to your operating system documentation for detailed instructions.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Chapter 1: Getting Started with the Command Line Utility
8
2
From the command prompt type
load cdrom
, then press
Enter
. From the command
prompt, type:
xx_yy_zz:\netware\manager\install
where
xx
is the product CD,
yy
is the version number, and
zz
is the release number. For
example:
adptcd_v2_01
The installation program starts.
3
Follow the on-screen instructions to complete the installation.
Installing on OpenServer and UnixWare
To install
ARCCONF
on OpenServer and UnixWare systems or
HRCONF on OpenServer
:
1
Insert the Adaptec Storage Manager installation CD in the CD drive.
2
Mount the Adaptec Storage Manager installation CD:
mount -r -F cdfs /dev/cdrom/cdromdevicefile /mnt
where
cdromdevicefile
is the device file, for example, c0b0t010, for the CD block device.
To determine the actual filename, look in the /dev/cdrom directory.
3
Use pkgadd to install Adaptec Storage Manager:
pkgadd -d /mnt/unixware/manager/RaidMan.ds (for UnixWare)
pkgadd -d /mnt/openserv6/manager/RaidMan.ds (for OpenServer 6)
4
Follow the instructions on the screen to complete the installation.
5
Unmount the CD drive:
umount /mnt
Installing on Solaris
Note:
HRCONF is not supported by systems running Solaris.
To install ARCCONF on Solaris systems:
1
Insert the Adaptec Storage Manager Installation CD.
The CD mounts automatically. (If it doesn’t, manually mount the CD using a command
similar to the one shown below. Refer to your operating system documentation for detailed
instructions.)
mount -F hsfs -o ro/dev/dsk/c1t0d0s2/mnt
2
Install Adaptec Storage Manager:
pkgadd -d/<mount point>/solaris/manager/StorMan.ds
3
Follow the on-screen instructions to complete the installation.
Eject or unmount the Adaptec Storage Manager Installation CD. Refer to your operating
system documentation for detailed instructions.