Asus DSEB-D16 SAS DSEB-D16 User's Manual for English Edition - Page 134
Checking the drives for data consistency, Using the Check Consistency
View all Asus DSEB-D16 SAS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
5.2.6 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected logical drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for logical drives included in a RAID 1 set. Using the Check Consistency To check data consistency using the Check Consistency command: 1. From the Management Menu, select Check Consistency, then press . LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007 Management Menu Configure Initialize Objects Rebuild Check Consistency CC Of VD(s) Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2. The screen displays the available RAID set(s) and prompts you to select the logical drive to check. Press the to select the logical drive from the Logical Drive selection, then press . LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007 Logical Drive(s) Configured Management Menu LD RAID Size #Stripes StripSz Status Configure Initialize 0 10 154494MB 4 64 KB ONLINE Objects Rebuild Check Consistency Logical Drives Loical Drive 0 Select VD SPACE-(De)Select, F10-Check Consistency 5-24 Chapter 5: RAID configuration