Asus PRIME A620-PLUS WIFI PRIME PROART TUF GAMING AMD AM5 Series BIOS Manual E - Page 79

Chassis Fan 1-5 Point2 Duty Cycle

Page 79 highlights

The following items appear only when Chassis Fan 1-5 Profile is set to [Manual]. Chassis Fan 1-5 Point4 Temperature When the temperature source is lower than the temperature of P4, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P4, the fan will operate at the duty cycle of P4. Use the or keys to adjust the Point4 temperature. Chassis Fan 1-5 Point4 Duty Cycle (%) When the temperature source is lower than the temperature of P4, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P4, the fan will operate at the duty cycle of P4. Use the or keys to adjust the Point4 temperature. Chassis Fan 1-5 Point3 Temperature When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. Use the or keys to adjust the Point3 temperature. Chassis Fan 1-5 Point3 Duty Cycle (%) When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. Use the or keys to adjust the Point3 temperature. Chassis Fan 1-5 Point2 Temperature When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. Use the or keys to adjust the Point2 temperature. Chassis Fan 1-5 Point2 Duty Cycle (%) When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. Use the or keys to adjust the Point2 temperature. Chassis Fan 1-5 Point1 Temperature When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to the P1-P2 and the temperature source. Use the or keys to adjust the Point1 temperature. Chassis Fan 1-5 Point1 Duty Cycle (%) When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to the P1-P2 and the temperature source. Use the or keys to adjust the Point1 temperature. Allow Fan Stop This function allows the fan to run at 0% duty cycle when the temperature of the source is dropped below the lower temperature. Configuration options: [Disabled] [Enabled] PRIME / ProArt / TUF GAMING AMD 600 Series BIOS Manual 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

PRIME / ProArt / TUF GAMING AMD 600 Series BIOS Manual
79
The following items appear only when
Chassis Fan 1-5 Profile
is set to
[Manual].
Chassis Fan 1-5 Point4 Temperature
When the temperature source is lower than the temperature of P4, the duty cycle will be
determined according to the P3-P4 and the temperature source. When the temperature
source is higher than the temperature of P4, the fan will operate at the duty cycle of P4.
Use the <+> or <-> keys to adjust the Point4 temperature.
Chassis Fan 1-5 Point4 Duty Cycle (%)
When the temperature source is lower than the temperature of P4, the duty cycle will be
determined according to the P3-P4 and the temperature source. When the temperature
source is higher than the temperature of P4, the fan will operate at the duty cycle of P4.
Use the <+> or <-> keys to adjust the Point4 temperature.
Chassis Fan 1-5 Point3 Temperature
When the temperature source is lower than the temperature of P3, the duty cycle will be
determined according to the P3-P4 and the temperature source. When the temperature
source is higher than the temperature of P3, the duty cycle will be determined according
to the P3-P4 and the temperature source. Use the <+> or <-> keys to adjust the Point3
temperature.
Chassis Fan 1-5 Point3 Duty Cycle (%)
When the temperature source is lower than the temperature of P3, the duty cycle will be
determined according to the P3-P4 and the temperature source. When the temperature
source is higher than the temperature of P3, the duty cycle will be determined according
to the P3-P4 and the temperature source. Use the <+> or <-> keys to adjust the Point3
temperature.
Chassis Fan 1-5 Point2 Temperature
When the temperature source is lower than the temperature of P2, the duty cycle will be
determined according to the P2-P3 and the temperature source. When the temperature
source is higher than the temperature of P2, the duty cycle will be determined according
to the P2-P3 and the temperature source. Use the <+> or <-> keys to adjust the Point2
temperature.
Chassis Fan 1-5 Point2 Duty Cycle (%)
When the temperature source is lower than the temperature of P2, the duty cycle will be
determined according to the P2-P3 and the temperature source. When the temperature
source is higher than the temperature of P2, the duty cycle will be determined according
to the P2-P3 and the temperature source. Use the <+> or <-> keys to adjust the Point2
temperature.
Chassis Fan 1-5 Point1 Temperature
When the temperature source is lower than the temperature of P1, the fan will operate at
the duty cycle of P1. When the temperature source is higher than the temperature of P1,
the duty cycle will be determined according to the P1-P2 and the temperature source.
Use the <+> or <-> keys to adjust the Point1 temperature.
Chassis Fan 1-5 Point1 Duty Cycle (%)
When the temperature source is lower than the temperature of P1, the fan will operate at
the duty cycle of P1. When the temperature source is higher than the temperature of P1,
the duty cycle will be determined according to the P1-P2 and the temperature source.
Use the <+> or <-> keys to adjust the Point1 temperature.
Allow Fan Stop
This function allows the fan to run at 0% duty cycle when the temperature of the source is
dropped below the lower temperature.
Configuration options: [Disabled] [Enabled]