Asus ROG MAXIMUS VIII EXTREME/ASSEMBLY MAXIMUS VIII EXTREME/ASSEMBLY Users man - Page 124
Chassis Fan 1-4 Max. Duty Cycle % [100]
View all Asus ROG MAXIMUS VIII EXTREME/ASSEMBLY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 124 highlights
Chassis Fan 1-4 Q-Fan Source [CPU] The assignment fan will be controlled according to the selected temperature source. Configuration options: [CPU] [MotherBoard] [VRM] [PCH] [T_SENSOR1] [T_ SENSOR2] [T_SENSOR3] [EXT_Sensor1] [EXT_Sensor2] [EXT_Sensor3] For EXT_Sensor1-3, connect a Thermistor cable to the EXT_TS1-3 header then place the other end to the component to get the temperature. Chassis Fan 1-4 Step Up [0 sec] This item allows you to set the value of the CPU fan step up. Configuration options: [0 sec] [12 sec] [25 sec] [51 sec] [76 sec] [102 sec] [127 sec] [153 sec] [178 sec] [204 sec] Chassis Fan 1-4 Step Down [0 sec] This item allows you to set the value of the CPU fan step down. Configuration options: [0 sec] [12 sec] [25 sec] [51 sec] [76 sec] [102 sec] [127 sec] [153 sec] [178 sec] [204 sec] Chassis Fan 1-4 Fan Speed Low Limit [200 RPM] This item allows you to disable or set the chassis fan warning speed. Configuration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM] Chassis Fan 1-4 Profile [Standard] This item allows you to set the appropriate performance level of the chassis fan. [Standard] Sets to [Standard] to make the chassis fan automatically adjust depending on the chassis temperature. [Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan operation. [Turbo] Sets to [Turbo] to achieve maximum chassis fan speed. [Manual] Sets to [Manual] to assign detailed fan speed control parameters. The following four items appear only when you set Chassis Fan 1-4 Profile to [Manual]. Chassis Fan 1-4 Upper Temperature [70] Use the or keys to adjust the upper limit of the Chassis Fan 1-4 temperature. The values range from 20 to 75. Chassis Fan 1-4 Max. Duty Cycle (%) [100] Use the or keys to adjust the maximum Chassis Fan 1-4 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the upper limit, the Chassis Fan 1-4 will operate at the maximum duty cycle. Chassis Fan 1-4 Middle Temperature [45] Use the or keys to adjust the middle limit of the Chassis Fan 1-4 temperature. The values range from 20 to 75. Chassis Fan 1-4 Middle. Duty Cycle (%) [60] Use the or keys to adjust the middle Chassis Fan 1-4 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the middle limit, the Chassis Fan 1-4 will operate at the middle duty cycle. Chapter 3 3-38 Chapter 3: BIOS Setup