Asus ROG MAXIMUS VIII EXTREME/ASSEMBLY MAXIMUS VIII EXTREME/ASSEMBLY Users man - Page 126
Anti Surge Support [On], Extension Fan 1-4 Middle. Duty Cycle % [60]
View all Asus ROG MAXIMUS VIII EXTREME/ASSEMBLY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 126 highlights
Extension Fan 1-4 Middle Temperature [45] Use the or keys to adjust the middle limit of the Extension Fan 1-4 temperature. The values range from 20 to 75. Extension Fan 1-4 Middle. Duty Cycle (%) [60] Use the or keys to adjust the middle Extension Fan 1-4 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the middle limit, the Extension Fan 1-4 will operate at the middle duty cycle. Extension Fan 1-4 Lower Temperature [40] Use the or keys to adjust the lower limit of the Extension Fan 1-4 temperature. The values range from 20 to 75. The Extension Fan 1-4 will operate at the minimum duty cycle when the temperature is lower than the limit. Extension Fan 1-4 Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum Extension Fan 1-4 duty cycle. The values range from 0% to 100%. When the CPU temperature is under the limit, the Extension Fan 1-4 will operate at the minimum duty cycle. Water Pump Control [Disabled] [Disabled] Disable the Water Pump control feature. [DC mode] Enable the Water Pump control in DC mode for 3-pin chassis fan. [PWM mode] Enable the Water Pump control in PWM mode for 4-pin chassis fan. Anti Surge Support [On] Enable this item for Over Voltage Protection (OVP) and Under Voltage Protection (UVP) functions. Configuration options: [On] [Off] Chapter 3 3-40 Chapter 3: BIOS Setup