Asus Z170-A User Guide - Page 102

Extension Fan 1-4 Min. Duty Cycle% [60]

Page 102 highlights

Extension Fan 1-3 Profile [Standard] This item allows you to set the appropriate performance level of the CPU fan. [Standard] Set to make the CPU fan adjust automatically depending on the CPU temperature. [Silent] Set to minimize the fan speed for quiet CPU fan operation. [Turbo] Set to achieve maximum CPU fan speed. [Manual] Set to assign the detailed fan speed control parameters. The following items appear only when you set the Extension Fan Profile to [Manual]. Extension Fan 1-4 Upper Temperature [70] Use the or keys to adjust the upper limit of the Extension Fan 1-4 temperature. The values range from 20 to 75. Extension Fan 1-4 Max. Duty Cycle (%) [100] Use the or keys to adjust the maximum Extension Fan 1-4 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the upper limit, the Extension Fan 1-4 will operate at the maximum duty cycle. Extension Fan 1-4 Middle Temperature [45] Use the or keys to adjust the middle limit of the Extension Fan 1-4 temperature. The values range from 20 to 75. Extension Fan 1-4 Middle. Duty Cycle (%) [60] Use the or keys to adjust the maximum Extension Fan 1-4 duty cycle. The values range from 20% to 100%. When the CPU temperature reaches the upper limit, the Extension Fan 1-4 will operate at the maximum duty cycle. Extension Fan 1-4 Lower Temperature [40] Use the or keys to adjust the lower limit of the Extension Fan 1-4 temperature. The values range from 20 to 75. The Extension Fan 1-4 will operate at the minimum duty cycle when the temperature is lower than the limit. Extension Fan 1-4 Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum Extension Fan 1-4 duty cycle. The values range from 0% to 100%. When the CPU temperature is under the limit, the Extension Fan 1-4 will operate at the minimum duty cycle. Water Pump Control [Disabled] [Disabled] Disable the Water Pump control feature. [DC mode] Enable the Water Pump control in DC mode for 3-pin chassis fan. [PWM mode] Enable the Water Pump control in PWM mode for 4-pin chassis fan. The following items appear only when you set the Water Pump Control to [DC mode] or [PWM mode]. Water Pump Upper Temperature [25] Use the or keys to adjust the upper limit of the Water Pump temperature. The values range from 20 to 75. 2-50 Chapter 2: BIOS Setup

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

2-50
Chapter 2: BIOS Setup
Extension Fan 1-3 Profile [Standard]
This item allows you to set the appropriate performance level of the CPU fan.
[Standard]
Set to make the CPU fan adjust automatically depending on the CPU
temperature.
[Silent]
Set to minimize the fan speed for quiet CPU fan operation.
[Turbo]
Set to achieve maximum CPU fan speed.
[Manual]
Set to assign the detailed fan speed control parameters.
The following items appear only when you set the Extension Fan Proļ¬le to
[Manual]
.
Extension Fan 1-4 Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the Extension Fan 1-4
temperature. The values range from 20 to 75.
Extension Fan 1-4 Max. Duty Cycle (%) [100]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-4 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Extension Fan 1-4 will operate at the maximum
duty cycle.
Extension Fan 1-4 Middle Temperature [45]
Use the <+> or <-> keys to adjust the middle limit of the Extension Fan 1-4
temperature. The values range from 20 to 75.
Extension Fan 1-4 Middle. Duty Cycle (%) [60]
Use the <+> or <-> keys to adjust the maximum Extension Fan 1-4 duty
cycle. The values range from 20% to 100%. When the CPU temperature
reaches the upper limit, the Extension Fan 1-4 will operate at the maximum
duty cycle.
Extension Fan 1-4 Lower Temperature [40]
Use the <+> or <-> keys to adjust the lower limit of the Extension Fan 1-4
temperature. The values range from 20 to 75. The Extension Fan 1-4 will
operate at the minimum duty cycle when the temperature is lower than the
limit.
Extension Fan 1-4 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum Extension Fan 1-4 duty
cycle. The values range from 0% to 100%. When the CPU temperature
is under the limit, the Extension Fan 1-4 will operate at the minimum duty
cycle.
Water Pump Control [Disabled]
[Disabled]
Disable the Water Pump control feature.
[DC mode]
Enable the Water Pump control in DC mode for 3-pin chassis fan.
[PWM mode]
Enable the Water Pump control in PWM mode for 4-pin chassis fan.
The following items appear only when you set the Water Pump Control to
[DC mode]
or
[PWM mode].
Water Pump Upper Temperature [25]
Use the <+> or <-> keys to adjust the upper limit of the Water Pump
temperature. The values range from 20 to 75.