Autodesk 00126-050008-1630A User Guide - Page 65

Example of an Image Calibration

Page 65 highlights

WiseImage - User's Guide Mean error indicates the average error of the method chosen. Also, pay attention to the Xerr and Yerr values to estimate the error of the chosen method for every point. Example of an Image Calibration This example shows the calibration of a color image from the UTRECHT.TIF file of the SAMPLES subfolder of the program root folder. Image loading Choose Open from the rFile menu. In the dialog box go to the SAMPLES folder and double-click the UTRECHT.TIF file name. - or - Select the UTRECHT.TIF file and press the Open button in the dialog box. Note that this image sample has raster grid with a X-axis of 2 cells and an Y-axis of 2 cells. The size of cells in this grid is known to be 32x32 mm, and in the original scanned image the grid cells are distorted. We assume that the whole image distortion corresponds to the grid distortion. Use calibration procedure to eliminate distortion. Open the Calibration dialog box From the rImage menu, choose Calibration or click the button on the WiseImage toolbar. Creating a set of calibration pairs using calibration grid 1. Press the button in the Calibration dialog box. The Calibration Grid dialog box appears. 2. Zoom to the image lower-left corner. 3. Enter the exact coordinates of the lower-left grid node to Origin the UCS is defined or press the Measure button and click a point at the raster lower- left grid node, as shown in the figure below. 66

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235

WiseImage – User’s Guide
66
Mean error
indicates the average error of the method chosen. Also, pay
attention to the
Xerr
and
Yerr
values to estimate the error of the chosen
method for every point.
Example of an Image Calibration
This example shows the calibration of a color image from the UTRECHT.TIF file of
the SAMPLES subfolder of the program root folder.
Image loading
Choose
Open
from the
rFile
menu.
In the dialog box go to the SAMPLES folder and double-click the
UTRECHT.TIF file name.
- or -
Select the UTRECHT.TIF file and press the
Open
button in the dialog box.
Note that this image sample has raster grid with a X-axis of 2 cells and an
Y-axis of 2 cells. The size of cells in this grid is known to be 32x32 mm, and in
the original scanned image the grid cells are distorted. We assume that the
whole image distortion corresponds to the grid distortion.
Use calibration procedure to eliminate distortion.
Open the Calibration dialog box
From the
rImage
menu, choose
Calibration
or click the
button on the
WiseImage
toolbar.
Creating a set of calibration pairs using calibration grid
1.
Press the
button in the
Calibration
dialog box. The
Calibration Grid
dialog
box appears.
2.
Zoom to the image lower-left corner.
3.
Enter the exact coordinates of the lower-left grid node to
Origin
the UCS is
defined or press the
Measure
button
and click a point at the raster lower-
left grid node, as shown in the figure below.