Behringer RX1202FX Manual - Page 9

Digital effects processor, Voltage supply, phantom power supply, and fuse - rack mount

Page 9 highlights

9 EURORACK PRO RX1202FX User Manual CD/TAPE TO MIX When the CD/TAPE TO MIX switch is pressed, the CD/tape input is assigned to the main mix providing an additional input for tape machines, MIDI instruments or other signal sources that do not require any processing. 2.5 Digital effects processor 2.6 Voltage supply, phantom power supply and fuse FUSE HOLDER/IEC MAINS RECEPTACLE The mains connection is made via a cable with an IEC mains connector and meets the required safety standards. An appropriate mains cable is supplied with the equipment. Blown fuses must only be replaced by fuses of the same type and rating. Fig. 2.6: Voltage supply and fuse Fig. 2.5: Effects section 100 FIRST-CLASS EFFECTS The EURORACK RX1202FX features a built-in digital stereo effects processor. This effects processor offers a large number of standard effects such as Hall, Chorus, Flanger, Delay and various combination effects. Using the FX control, you can feed signals into the effects processor. The integrated effects module has the advantage of requiring no wiring. This way, the danger of creating ground loops or uneven signal levels is eliminated at the outset, completely simplifying the handling. SIG and CLIP LED The SIG LED on the effects module shows the presence of a signal whose level is high enough. This LED should always be on. However, make sure that the CLIP LED lights up only sporadically. If it is lit constantly, you are overdriving the effects processor, which leads to unpleasant distortion. If this occurs, turn the FX controls down somewhat. PROGRAM The PROGRAM control has two functions: by turning the PROGRAM control, you dial the number of an effect. The number of the preset you just dialed up blinks in the display. To confirm your selection, press the PROGRAM control; the blinking stops. FX TO MAIN By using the FX TO MAIN controller, the effects signal is sent to the main mix. No effects signal is to be heard in the summed signal of the mixer when the controller is positioned entirely to the left. Choose this position if you want to use an external effects device for the FX output. An overview of all the multieffect processor's presets are to be found in the appendix. POWER switch Use the POWER switch to turn on the mixing console. The POWER switch should always be in the "Off" position when you are about to connect your unit to the mains. To disconnect the unit from the mains, pull out the main cord plug. When installing the product, ensure that the plug is easily accessible. If mounting in a rack, ensure that the mains can be easily disconnected by a plug pull or by an all-pole disconnect switch on or near the rack. ◊ Attention: The POWER switch does not fully disconnect the unit from the mains. Unplug the power cord completely when the unit is not used for prolonged periods of time. PHANTOM switch The PHANTOM switch activates the phantom power (necessary to operate condenser microphones) on the XLR sockets of the mono channels. The red +48 V LED illuminates when phantom power is on. As a rule, dynamic microphones can still be used with phantom power, provided that they are wired in a balanced configuration. In case of doubt, contact the microphone manufacturer! ◊ Connect microphones before you switch on the phantom power supply. Please do not connect microphones to the mixer (or the stagebox/ wallbox) while the phantom power supply is switched on. In addition, the monitor/PA loud-speakers should be muted before you activate the phantom power supply. After switching on, wait approx. one minute to allow for system stabilization. ◊ Caution! Please also note the information given in chapter 4.2 "Audio connections". SERIAL NUMBER Please note the important information on the serial number given in chapter 1.3.3.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

9
EURORACK PRO RX1202FX User Manual
CD/TAPE TO MIX
When the
CD/TAPE TO MIX
switch is pressed, the CD/tape input is assigned to
the main mix providing an additional input for tape machines, MIDI instruments
or other signal sources that do not require any processing.
2.5
Digital effects processor
Fig. 2.5: Effects section
100 FIRST-CLASS EFFECTS
The EURORACK RX1202FX features a built-in digital stereo effects processor.
This effects processor offers a large number of standard effects such as Hall,
Chorus, Flanger, Delay and various combination effects. Using the FX control,
you can feed signals into the effects processor. The integrated effects
module has the advantage of requiring no wiring. This way, the danger of
creating ground loops or uneven signal levels is eliminated at the outset,
completely simplifying the handling.
SIG and CLIP LED
The
SIG
LED on the effects module shows the presence of a signal whose level
is high enough. This LED should always be on. However, make sure that the
CLIP
LED lights up only sporadically. If it is lit constantly, you are overdriving
the effects processor, which leads to unpleasant distortion. If this occurs,
turn the FX controls down somewhat.
PROGRAM
The
PROGRAM
control has two functions: by
turning
the
PROGRAM
control,
you dial the number of an effect. The number of the preset you just dialed up
blinks in the display. To confirm your selection,
press
the PROGRAM control;
the blinking stops.
FX TO MAIN
By using the
FX TO MAIN
controller, the effects signal is sent to the main mix.
No effects signal is to be heard in the summed signal of the mixer when the
controller is positioned entirely to the left. Choose this position if you want to
use an external effects device for the FX output.
An overview of all the multieffect processor’s presets are to be found in
the appendix.
2.6
Voltage supply, phantom power supply
and fuse
FUSE HOLDER/IEC MAINS RECEPTACLE
The mains connection is made via a cable with an IEC mains connector and
meets the required safety standards. An appropriate mains cable is supplied
with the equipment. Blown fuses must only be replaced by fuses of the same
type and rating.
Fig. 2.6: Voltage supply and fuse
POWER switch
Use the
POWER
switch to turn on the mixing console. The POWER switch
should always be in the “Off” position when you are about to connect your unit
to the mains.
To disconnect the unit from the mains, pull out the main cord plug.
When installing the product, ensure that the plug is easily accessible.
If mounting in a rack, ensure that the mains can be easily disconnected
by a plug pull or by an all-pole disconnect switch on or near the rack.
Attention: The POWER switch does not fully disconnect the unit from
the mains. Unplug the power cord completely when the unit is not
used for prolonged periods of time.
PHANTOM switch
The
PHANTOM
switch activates the phantom power (necessary to operate
condenser microphones) on the XLR sockets of the mono channels.
The red
+48 V
LED illuminates when phantom power is on. As a rule,
dynamic microphones can still be used with phantom power, provided that
they are wired in a balanced configuration. In case of doubt, contact the
microphone manufacturer!
Connect microphones before you switch on the phantom power supply.
Please do not connect microphones to the mixer (or the stagebox/
wallbox) while the phantom power supply is switched on. In addition,
the monitor/PA loud-speakers should be muted before you activate the
phantom power supply. After switching on, wait approx. one minute to
allow for system stabilization.
Caution! Please also note the information given in chapter 4.2
“Audio connections”.
SERIAL NUMBER
Please note the important information on the serial number given in
chapter 1.3.3.