ULTRALINK UL2000M 6.2 ULM2000 microphone RF characteristics Modulation Frequency range Transmission frequencies (for EU/US/CA) Channels Channel bandwidth Channel spacing (min.) Nominal/peak deviation Frequency stability Antenna Range wideband FM 794 - 810 MHz 320 frequencies, between 798.1 - 805.9 MHz, adjustable in 25-kHz increments 8, freely programmable and switchable < 200 kHz 400 kHz ± 32 kHz / ± 48 kHz < ± 15 ppm integrated 100 m (nominal), coupled with the ULR2000 receiver under optimal environmental conditions AF characteristics (coupled to ULR2000) Noise reduction high-performance compander system, Pre-/Deemphase RF system AF frequency response 30 - 19000 Hz (-3dB) THD (at nom. deviation and 1kHzNF) SNR (at peak deviation) < 0.4 % > 105 dB (A) Microphone Type Pickup pattern Sensitivity Frequency resonse curve Max. input sound pressure SNR Panasonic® back electret condenser with FET impendance converter Unidirectional (cardioid) -47 dB (0 dB = 1 V/Pa, 1 kHz) 100 - 18000 Hz > 120 dB SPL > 60 dB Temperature range 14°F - 122°F (-10°C to +50°C) In compliance with ETS 300 445, ETS 300 422, FCC Power supply Power consumption Standby current Operating time 2 x 9 V alkaline cell (IEC 6LR61-PP3) typ. 75 mA typ. 31 mA > 12 hours Dimensions/Weight Dimensions (W x H x D) Weight approx. 1 7/8" x 10" x 1 7/8" (48 mm x 254 mm x 48 mm) approx. 0.5 lbs (0.250 kg) BEHRINGER makes every effort to ensure the highest standards of quality. Necessary modifications are carried out without notice. Thus, the specifications and design of the device may differ from the information given in this manual. Technical specifications and appearance subject to change without notice. The information contained herein is correct at the time of printing. The names of companies, institutions or publications pictured or mentioned and their respective logos are registered trademarks of their respective owners. Their use neither constitutes a claim of the trademarks by BEHRINGER nor affiliation of the trademark owners with BEHRINGER. BEHRINGER accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement contained herein. Colors and specification may vary slightly from product. Products are sold through our authorised dealers only. Distributors and dealers are not agents of BEHRINGER and have absolutely no authority to bind BEHRINGER by any express or implied undertaking or representation. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording of any kind, for any purpose, without the express written permission of BEHRINGER International GmbH. BEHRINGER is a registered trademark. ALL RIGHTS RESERVED. © 2008 BEHRINGER International GmbH, Hanns-Martin-Schleyer-Str. 36-38, 47877 Willich-Münchheide II, Germany. Tel. +49 2154 9206 0, Fax +49 2154 9206 4903 22 6. SPECIFICATIONS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

22
ULTRALINK UL2000M
6.2 ULM2000 microphone
RF characteristics
Modulation
wideband FM
Frequency range
794 - 810 MHz
Transmission frequencies (for EU/US/CA)
320 frequencies, between 798.1 - 805.9 MHz,
adjustable in 25-kHz increments
Channels
8, freely programmable and switchable
Channel bandwidth
< 200 kHz
Channel spacing (min.)
400 kHz
Nominal/peak deviation
± 32 kHz / ± 48 kHz
Frequency stability
< ± 15 ppm
Antenna
integrated
Range
100 m (nominal), coupled with the ULR2000 receiver under
optimal environmental conditions
AF characteristics (coupled to ULR2000)
Noise reduction
high-performance compander system, Pre-/Deemphase
RF system AF frequency response
30 - 19000 Hz (-3dB)
THD (at nom. deviation and 1kHz
NF
)
< 0.4 %
SNR (at peak deviation)
> 105 dB (A)
Microphone
Type
Panasonic
®
back electret condenser
with FET impendance converter
Pickup pattern
Unidirectional (cardioid)
Sensitivity
-47 dB (0 dB = 1 V/Pa, 1 kHz)
Frequency resonse curve
100 - 18000 Hz
Max. input sound pressure
> 120 dB SPL
SNR
> 60 dB
Temperature range
14°F - 122°F (-10°C to +50°C)
In compliance with
ETS 300 445, ETS 300 422, FCC
Power supply
2 x 9 V alkaline cell (IEC 6LR61-PP3)
Power consumption
typ. 75 mA
Standby current
typ. 31 mA
Operating time
> 12 hours
Dimensions/Weight
Dimensions (W x H x D)
approx. 1 7/8" x 10" x 1 7/8" (48 mm x 254 mm x 48 mm)
Weight
approx. 0.5 lbs (0.250 kg)
BEHRINGER makes every effort to ensure the highest standards of quality. Necessary modifications are carried out without notice.
Thus, the specifications and design of the device may differ from the information given in this manual.
Technical specifications and appearance subject to change without notice. The information contained herein is correct at the time of printing. The
names of companies, institutions or publications pictured or mentioned and their respective logos are registered trademarks of their respective
owners. Their use neither constitutes a claim of the trademarks by BEHRINGER nor affiliation of the trademark owners with BEHRINGER.
BEHRINGER accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description,
photograph or statement contained herein. Colors and specification may vary slightly from product. Products are sold through our authorised
dealers only. Distributors and dealers are not agents of BEHRINGER and have absolutely no authority to bind BEHRINGER by any express or
implied undertaking or representation. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording of any kind, for any purpose, without the express written permission of BEHRINGER International
GmbH. BEHRINGER is a registered trademark.
ALL RIGHTS RESERVED. © 2008 BEHRINGER International GmbH,
Hanns-Martin-Schleyer-Str. 36-38, 47877 Willich-Münchheide II, Germany.
Tel. +49 2154 9206 0, Fax +49 2154 9206 4903
6. SPECIFICATIONS