Beko BD532A User Manual - Page 11
Neutral
View all Beko BD532A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Electrical connection Connect the product to a grounded outlet/line protected by a fuse of suitable capacity as stated in the "Technical specifications" table. Have the grounding installation made by a qualified electrician while using the product with or without a transformer. Our company shall not be liable for any damages that will arise due to using the product without a grounding installation in accordance with the local regulations. ADANGER • Risk of electric shock, short circuit or fire by unprofessional installation! The appliance may be connected to the mains supply only by an authorized qualified person and the appliance is only guaranteed after correct installation. /i \DANGER • Risk of electric shock, short circuit or fire by damage of the mains lead! The mains lead must not be clamped, bent or trapped or come into contact with hot parts of the appliance. If the mains lead is damaged, it must be replaced by a qualified electrician. The mains supply data must correspond to the data specified on the type label of the product. The rating plate is either seen when the door or the lower cover is opened or it is located at the rear wall of the unit depending on the unit type. Power cable of your product must comply with the values in "Technical specifications" table. A, DANGER r'Ivit \RBeisfkoroefsetalertcintrgicasnhyowcokr!k on the electrical installation, please disconnect the appliance from the mains supply. Connecting the power cable 1. If a power cable is not supplied together with your product,a power cable that you would select from the table in accordance with the e ectrical installation at your home must be connected to your product by following the instructions in cab e diagram. (P ease consider technical data table, Technical specifications, page 5) This product must only be installed by a qualified electrician eg local electricity company or NICEIC registered contractor to a suitable double-pole control unit with a minimum contact clearance of 3mm in a I poles and with a m nimum rating please consider technical data table, Technical specifications, page 5 which should be fitted ad,acent to (but not above) the cooker in accordance with EE regulations. Failure to observe this instruction may result in operationa problems and invalidation of the product warranty. dditional protection by a residual urrent circuit breaker is ecommended. 2. The cable must have conductors of sufficiently high cross sectional area to prevent overheating and deterioration. The mains cable must conform to BS6004. This appliance must be earthed. The mains cable must pass through the cable clamp. The mains cable should be routed away from the appliance and in particular ventilation slots, the vent outlet and should not be obstructed when pushed in to position between the appliance and the wall and/or cabinets. 3. Open the terminal block cover with a screwdriver. 4. Insert the power cable through the cable clamp below the terminal and secure it to the main body with the integrated screw on cable clamping component. 5. Connect the cables according to the supplied diagram. 2 NEUTRAL EAR L. PLY CORD 6. After completing the wire connections, close the terminal block cover. 10 / EN