Beko HIC64102 User Manual - Page 10
location
View all Beko HIC64102 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
location Assembly of the Built-in Hob This built-in hob must be installed into a recess in a work surface. Installation and electrical connections should be performed by a suitably qualified technician in accordance with the regulations in force. The appliance should be connected to a suitable easily accessable double pole control unit with a minimum contact clearance of 3 mm with a minimum rating of 30 amps fitted adjacent too (but not above the hob where it could be affected by heat or steam). Allow 55 mm clearance from one high side wall to the side corner. If a cooker is to be fitted underneath the hob, it must be ventilated. 5.5 cm (min) 56 c 6 cm (min) 49 cm 5 cm (min ) You can install your hob according to the illustrated figure by means of assembly clamps. The assembly clamp may vary dependant on your model. 9