Belkin PF60 AP41300-12 User Manual - Page 20

Operation

Page 20 highlights

PureAV Power Console Operation Central LCD Control Panel The PureAV Power Console PF60 is equipped with an advanced LCD Control Panel. Most functions of the Power Console can be monitored from this display. A. PureFilter Indicator - indicates that the multiphase PureFilter circuitry is functioning properly. B. Voltmeter - displays the input voltage (the amount of voltage coming from the AC wall outlet to the Power Console). C. Current Meter - displays the output current (the amount of current output [in Amps] from the Power Console's outlet banks). You can choose to see the current output from all of the banks at the same time or individual banks using the "Bank Selector" button. D. Outlet Banks - displays the currently selected bank for monitoring output current (controlled with the "Bank" button). E. Wiring - indicates whether the AC outlet to which the Power Console is connected is wired properly, or cross-wired. Wiring ok. Hot and neutral wires are reversed. See page 22 of the Troubleshooting section for more information. F. Ground - Indicates if the Power Console is connected to a properly grounded AC outlet. Ground ok. The AC wall outlet is properly grounded. Ground Fault. This indicates that the AC wall outlet is NOT properly grounded. See page 22 of the Troubleshooting section for more information. G. Switched Indicator - indicates whether the "Switched" outlets are switched ON or OFF. H. Timed Delay Indicator - indicates that the delayed outlets are switched ON after a delay. I. Remote Indicator - indicates whether the Remote function is ON or OFF (controlled with the "Remote" button). J. Remote Button - switches the Power Console to Remote ON status when pressed. (When in Remote ON status, the Power Console outlets programmed as switched are turned ON/OFF via external remote signal [see page 10-11.]) 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

19
PureAV Power Console
Operation
Central LCD Control Panel
The PureAV Power Console PF60 is equipped with an advanced LCD
Control Panel. Most functions of the Power Console can be monitored
from this display.
A. PureFilter Indicator –
indicates that the multiphase PureFilter circuitry
is functioning properly.
B. Voltmeter –
displays the input voltage (the amount of voltage coming
from the AC wall outlet to the Power Console).
C. Current Meter –
displays the output current (the amount of current
output [in Amps] from the Power Console’s outlet banks). You can
choose to see the current output from all of the banks at the same
time or individual banks using the “Bank Selector” button.
D. Outlet Banks –
displays the currently selected bank for monitoring
output current (controlled with the “Bank” button).
E. Wiring –
indicates whether the AC outlet to which the Power Console
is connected is wired properly, or cross-wired.
Wiring ok.
Hot and neutral wires are reversed. See page 22 of the
Troubleshooting section for more information.
F.
Ground –
Indicates if the Power Console is connected to a properly
grounded AC outlet.
Ground ok. The AC wall outlet is properly grounded.
Ground Fault. This indicates that the AC wall outlet is NOT properly
grounded. See page 22 of the Troubleshooting section for more
information.
G. Switched Indicator –
indicates whether the “Switched” outlets are
switched ON or OFF.
H. Timed Delay Indicator –
indicates that the delayed outlets are
switched ON after a delay.
I.
Remote Indicator –
indicates whether the Remote function is ON or
OFF (controlled with the “Remote” button).
J.
Remote Button –
switches the Power Console to Remote ON status
when pressed. (When in Remote ON status, the Power Console outlets
programmed as switched are turned ON/OFF via external remote
signal [see page 10-11.])