Cleaning the Separator 1 2 Press the tank release button and pull handle to lift dirt container away from vacuum. Remove the separator by twisting to the left (counterclockwise), then pull it out through the bottom of the tank. Rinse and dry all sections of dirt container with paper towel. Replace the Brush & Belt 1 2 3 Unplug vacuum, turn over and unscrew 6 Philips head screws to remove bottom cover. Lift roller straight out. Inspect belt, replace if it appears damaged. If the belt is not broken, remove roller from inside of looped belt. Inspect brush roll by placing it on its end and spin. The brush roll should spin freely, multiple times by one flick. If it doesn't, replace brush roll. 4 5 End Cap Belt Replace the brush roll and belt by looping the belt over the motor shaft and the brush roll. Line up the end caps and pull the brush forward into place. This will stretch the belt. Once the brush roll is installed, place the bottom cover back on and replace the screws. www.BISSELL.com 9