Bosch 53514B Operating Instructions - Page 15

Accessories

Page 15 highlights

BM 2610925944 6-05 6/10/05 11:50 AM Page 15 can cause the tool to operate improperly or damage the charger. Long term battery storage should be in the discharged state. Battery packs last longer and re-charge better when they are stored discharged. Remember to fully recharge battery packs before using after prolonged storage. TOOL LUBRICATION Your Bosch tool has been properly lubricated and is ready for use. D.C. MOTORS The motor in your tool has been engineered for many hours of dependable service. To maintain peak efficiency of the motor, we recommend it be examined every six months. Only a genuine Bosch replacement motor specially designed for your tool should be used. Cleaning ! WARNING To avoid accidents, always disconnect the tool and/or charger from the power supply before cleaning. The tool may be cleaned most effectively with compressed dry air. Always wear safety goggles when cleaning tools with compressed air. Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not attempt to clean by inserting pointed objects through opening. ! CAUTION Certain cleaning agents and solvents damage plastic parts. Some of these are: gasoline, carbon tetrachloride, chlorinated cleaning solvents, ammonia and household detergents that contain ammonia. Accessories ! WARNING If an extension cord is necessary, a cord with adequate size conductors that is capable of carrying the current necessary for your tool must be used. This will prevent excessive voltage drop, loss of power or overheating. Grounded tools must use 3-wire extension cords that have 3-prong plugs and receptacles. NOTE: The smaller the gauge number, the heavier the cord. RECOMMENDED SIZES OF EXTENSION CORDS 120 VOLT ALTERNATING CURRENT TOOLS Tool's Ampere Rating Cord Size in A.W.G. Wire Sizes in mm2 Cord Length in Feet Cord Length in Meters 25 50 100 150 15 30 60 120 3-6 6-8 8-10 10-12 12-16 18 16 16 14 18 16 14 12 18 16 14 12 16 16 14 12 14 12 - - 0.75 0.75 1.5 2.5 0.75 1.0 2.5 4.0 0.75 1.0 2.5 4.0 1.0 2.5 4.0 - --- - (*= standard equipment) (**= optional accessories) * Standard parallel width guide fence ** Deluxe angle fence ** Rabbeting depth stop * Blade wrench 2.5mm * Carbide reversible blades (2) * Vacuum connector ** Vacuum hose ** Chip bag ** 15 minute charger ** 30 minute charger (single bay) ** 30 minute charger (dual bay) ** 1 hour charger -15-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

can cause the tool to operate improperly or
damage the charger.
Long term battery storage should be in
the discharged state.
Battery packs last
longer and re-charge better when they are
stored discharged.
Remember to fully re-
charge battery packs before using after
prolonged storage.
TOOL LUBRICATION
Your Bosch tool has been properly lubricated
and is ready for use.
D.C. MOTORS
The motor in your tool has been engineered
for many hours of dependable service. To
maintain peak efficiency of the motor, we
recommend it be examined every six months.
Only a genuine Bosch replacement motor
specially designed for your tool should be
used.
Cleaning
To avoid accidents, always
disconnect the tool and/or
charger from the power supply before
cleaning.
The tool may be cleaned most
effectively with compressed dry air.
Always
wear safety goggles when cleaning tools
with compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through opening.
Certain cleaning agents
and
solvents
damage
plastic parts.
Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
!
WARNING
!
CAUTION
-15-
Accessories
If an extension cord is
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used.
This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-wire
extension cords that have 3-prong plugs and
receptacles
.
NOTE:
The smaller the gauge number, the
heavier the cord.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
!
WARNING
Tool’s
Ampere
Rating
Cord Size in A.W.G.
Wire Sizes in mm
2
3-6
6-8
8-10
10-12
12-16
18
16
16
14
0.75 0.75
1.5
2.5
18
16
14
12
0.75
1.0
2.5
4.0
18
16
14
12
0.75
1.0
2.5
4.0
16
16
14
12
1.0
2.5
4.0
14
12
25
50
100
150
15
30
60
120
Cord Length in Feet
Cord Length in Meters
(*= standard equipment)
(**= optional accessories)
*
Standard parallel width guide fence
**
Deluxe angle fence
**
Rabbeting depth stop
*
Blade wrench 2.5mm
*
Carbide reversible blades (2)
*
Vacuum connector
**
Vacuum hose
**
Chip bag
**
15 minute charger
**
30 minute charger (single bay)
**
30 minute charger (dual bay)
**
1 hour charger
BM 2610925944 6-05
6/10/05
11:50 AM
Page 15