Bosch HDS8055U Installation Instructions - Page 17

Attach the insulated grounding wire to the grounding

Page 17 highlights

Four-wire range cord connection (recommended method) 1. Disconnect the electrical power at the breaker box. Remove the terminal block cover to expose the terminal block. 2. If you need a lager hole for the strain relief (not provided with range) remove the metal plate. Rotate it 180° to have the lager hole for the power supply cable and mount it again. 5. Remove the grounding strap from the center post on the terminal block. Therefore remove the hexagonal nut of the neutral pin. Remove the fork type connector of the groundling link. Mount the hexagonal nut on the neutral pin again. Remove the green hexagonal screw and the ring connector from the grounding. The strap will not be needed. Remove it from the unit. 3. Insert the power supply cable into the terminal block through the bottom hole. 4. Mount strain relief (not provided with range) through the hole of the metal plate in the back panel located below the terminal block and secure tightly. Route the wires of the power supply cable through the strain relief and tighten clamp. 6. Attach the insulated grounding wire to the grounding hole with the green grounding screw. Tighten the green hexagonal nut firmly, but do not overtighten. 7. Insert the flat washer. 8. Attach the red wire to the left junction block terminal using one of the hexagonal nuts. Note: Make sure the strain relief is secured properly. 9. Attach the white wire to the center junction block terminal using one of the hexagonal nuts. 10.Attach the black wire to the right junction block terminal using one of the hexagonal nuts. 11.Tighten all connections securely and replace terminal block cover. Note: Do not plug in the range at this time. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

17
Four-wire range cord connection (recommended
method)
1.
Disconnect the electrical power at the breaker box.
Remove the terminal block cover to expose the
terminal block.
2.
If you need a lager hole for the strain relief (not
provided with range) remove the metal plate. Rotate it
180° to have the lager hole for the power supply cable
and mount it again.
3.
Insert the power supply cable into the terminal block
through the bottom hole.
4.
Mount strain relief (not provided with range) through
the hole of the metal plate in the back panel located
below the terminal block and secure tightly. Route the
wires of the power supply cable through the strain
relief and tighten clamp.
Note:
Make sure the strain relief is secured properly.
5.
Remove the grounding strap from the center post on
the terminal block. Therefore remove the hexagonal
nut of the neutral pin. Remove the fork type connector
of the groundling link. Mount the hexagonal nut on the
neutral pin again. Remove the green hexagonal screw
and the ring connector from the grounding. The strap
will not be needed. Remove it from the unit.
6.
Attach the insulated grounding wire to the grounding
hole with the green grounding screw. Tighten the
green hexagonal nut firmly, but do not overtighten.
7.
Insert the flat washer.
8.
Attach the red wire to the left junction block terminal
using one of the hexagonal nuts.
9.
Attach the white wire to the center junction block
terminal using one of the hexagonal nuts.
10.
Attach the black wire to the right junction block
terminal using one of the hexagonal nuts.
11.
Tighten all connections securely and replace terminal
block cover.
Note:
Do not plug in the range at this time.