Bosch NGT745UC Installation Instructions - Page 6

Cutout Dimensions

Page 6 highlights

Countertop Requirements Figure 2 - Cutout Dimensions 6" (152.4mm) Min to Left Side Wall 3" (76.2 mm) Min. to Right Side Wall 1-3/4" (44.5 mm) Min. to Combustible Wall 21" (533.4 mm) cooktop depth 4" (101.6mm) Below Countertop 1/8" (3.5mm) Min Clearance from Cooktop to Start of Radius 2 1/4" (57.2mm) Min. to Counter Front 3" (76.2 mm) Min. to Back Wall 7-3/8"(187.8 mm) Min. to Left Side Wall 4 3/8" (111.6mm) Min. to Right Side Wall Gas Requirements Supply Pressure Propane Gas Installation (NGT Models only) English 4 Table 1: Cutout Dimensions Fig. 2 30" Models A - Cutout B - Cutout C - Corner D - Overall 19-1/8" to 19-7/8" (486.1mm) to (505.6mm) 28-5/8" to 29-3/8" (727.2mm) to (746.6mm) 30" (762mm) 31" (787.4mm) 36" Models 19-1/8 to 19-7/8" (486.1mm) to (505.6mm) 34-5/8" to 35-5/8" (879.6mm) to (899mm) 36" (914.4mm) 37" (939.8mm) • Natural Gas - 6 inches water column (14.9 Millibars) minimum. • Propane Gas -11 inches water column (27.4 Millibars) minimum. NOTE: NGP models cannot be converted for propane use. The propane gas tank must be equipped with its own high pressure regulator in addition to the pressure regulator supplied with this unit. The cooktop is shipped from the factory for use with natural gas. For use with LP, a conversion kit is required and must be purchased separately. Contact BSH or your retailer to obtain kit # NEZ1065. A qualified technician or installer must do the conversion. Leak testing of the appliance shall be conducted according to manufacturerís instructions.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

English 4
Countertop Requirements
Figure 2 - Cutout Dimensions
Gas Requirements -
Supply Pressure
Natural Gas
- 6 inches water column (14.9 Millibars) minimum.
Propane Gas
-11 inches water column (27.4 Millibars) minimum.
Propane Gas Installation
(NGT Models only)
NOTE:
NGP models cannot be converted for propane use.
The propane gas tank must be equipped with its own high pressure regulator in
addition to the pressure regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP,
a conversion kit is
required and must be purchased separately. Contact BSH or your retailer to obtain
kit # NEZ1065.
A qualified technician or installer must do the conversion.
Leak testing of the appliance shall be conducted according to manufacturerís
instructions.
4” (101.6mm) Below Countertop
21” (533.4 mm) cooktop depth
Side Wall
7-3/8”(187.8 mm)
Min. to Counter
1/8” (3.5mm)
6” (152.4mm) Min
Combustible Wall
Right Side Wall
3” (76.2 mm) Min. to
1-3/4” (44.5 mm) Min. to
to Left Side Wall
Min Clearance
from Cooktop to
2 1/4” (57.2mm)
Start of Radius
Left Side Wall
4 3/8”
(111.6mm)
to Back Wall
3” (76.2 mm) Min.
Min. to Right
Min. to
Front
Table 1: Cutout Dimensions
Fig. 2
30” Models
36” Models
A - Cutout
19-1/8” to 19-7/8”
(486.1mm) to
(505.6mm)
19-1/8 to 19-7/8”
(486.1mm) to
(505.6mm)
B - Cutout
28-5/8” to 29-3/8”
(727.2mm) to
(746.6mm)
34-5/8” to 35-5/8”
(879.6mm) to (899mm)
C - Corner
30” (762mm)
36” (914.4mm)
D - Overall
31” (787.4mm)
37” (939.8mm)