Brother International BAS-311F-0 Instruction Manual - English - Page 69

Changing Special Function And Using The Memory Switches, Memory Switches 30 - 3f

Page 69 highlights

11. CHANGING SPECIAL FUNCTION AND USING THE MEMORY SWITCHES Memory switches (30 - 3F) Turn the dial while pressing the STEP BACK switch to change the values. Switch No. memo-30 memo-31 memo-32 memo-33 memo-34 memo-35 memo-36 memo-37 memo-38 memo-39 memo-3A memo-3b Possible setting range 1 - 999 1 - 4 1 - 7 1 - 10 1 - 5 10 - 60 1 - 3 0 - 3 1 - 20 0 - 11 1 - 3 - Units X 10ms X 7.5 stitch ms X 100 ms - - - Initial Value 10 1 3 5 Explanation Time until feed mechanism starts moving after work clamp has lifted. Changes the feed speed. 1 (Fast) 4 (Slow) Changes the possible sewing speed for a given stitch length. 1 (Fast) 7 (Slow) 1 (2,700/3 mm), 2 (2,600/3 mm), 3 (2,500/3 mm), 4 (2,300/3 mm), 5 (2,000/3 mm), 6 (1,800/3 mm), 7 (1,200/3 mm) Settings 1 and 2 are outside the warranty specification at the time of shipment from the factory.) Changes the feed timing. 1 (Fast) 5 (standard) 10 (Slow) 1 Number of low-speed stitches sewn at 400 rpm at sewing start. Solenoid ON time changes (BAS-311F solenoid specifications 40 only). 10 (Quiet) 60 (High work clamp capacity) 1 The solenoid ON time when the presser foot is raised changes. (Standard) 1 3 (Upper limit) Automatically corrects the gear speed when reading 2DD disks. 0 : No automatic correction 0 1 : Read as BAS-311A data 2 : Read as BAS-326A data 3 : Read as BAS-341A, 342A data ex. Read BAS-326A data by BAS-311F / Set memo-37=2 Changes the length of time from inserting the cassette until 1 automatic starting when the eject device is being used and automatic starting has been set (memo-03 and DIP switch A-7 are also both ON). Changes the reference point for enlargement and reduction using the operation panel. 0 : Sensor home position 1 : Center of work clamp 2 : Upper-left corner of work clamp 3 : Lower-left corner of work clamp 0 4 : Upper-right corner of work clamp 5 : Lower-right corner of work clamp 6 : Sewing start point, 7 : Sewing end point 8 : Upper-left corner of sewing pattern 9 : Lower-left corner of sewing pattern 10 : Upper-right corner of sewing pattern 11 : Lower-right corner of sewing pattern Changes the speed limit for the given sewing pitch when the maximum speed remains constant. 1 : Speed limit is increased for the given sewing pitch and the sewing speed for that pitch is increased. 2 : Standard 2 3 : Speed limit is decreased for the given sewing pitch and the sewing speed for that pitch is decreased. Note If sewing slippage occurs in places where a large sewing pitch is used, reduce the setting to 3. Furthermore, sewing slippage may occur in some cases if setting 1 is used. 0- memo-3c - - 0- memo-3d - - 0- memo-3E - - 0- memo-3F - - 0 BAS-311F-0, 311F-L, 326F-0 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

11. CHANGING SPECIAL FUNCTION AND USING THE MEMORY SWITCHES
BAS-311F-0, 311F-L, 326F-0
62
Memory switches (30 - 3F)
Turn the dial while pressing the STEP BACK switch to change the values.
Switch No.
Possible
setting range
Units
Initial
Value
Explanation
memo-30
1 - 999
X 10ms
10
Time until feed mechanism starts moving after work clamp has
lifted.
memo-31
1 - 4
-
1
Changes the feed speed.
1 (Fast)
4 (Slow)
memo-32
1 - 7
-
3
Changes the possible sewing speed for a given stitch length.
1 (Fast)
7 (Slow)
1 (2,700/3 mm), 2 (2,600/3 mm), 3 (2,500/3 mm),
4 (2,300/3 mm), 5 (2,000/3 mm), 6 (1,800/3 mm), 7 (1,200/3 mm)
Settings 1 and 2 are outside the warranty specification at the
time of shipment from the factory.)
memo-33
1 - 10
X 7.5
5
Changes the feed timing.
1 (Fast)
5 (standard)
10 (Slow)
memo-34
1 - 5
stitch
1
Number of low-speed stitches sewn at 400 rpm at sewing start.
memo-35
10 - 60
ms
40
Solenoid ON time changes (BAS-311F solenoid specifications
only).
10 (Quiet)
60 (High work clamp capacity)
memo-36
1 - 3
-
1
The solenoid ON time when the presser foot is raised changes.
(Standard) 1
3 (Upper limit)
memo-37
0 - 3
-
0
Automatically corrects the gear speed when reading 2DD disks.
0 : No automatic correction
1 : Read as BAS-311A data
2 : Read as BAS-326A data
3 : Read as BAS-341A, 342A data
ex. Read BAS-326A data by BAS-311F / Set memo-37=2
memo-38
1 - 20
X 100 ms
1
Changes the length of time from inserting the cassette until
automatic
starting when the eject device is being used and automatic starting has
been set (memo-03 and DIP switch A-7 are also both ON).
memo-39
0 - 11
-
0
Changes the reference point for enlargement and reduction using
the operation panel.
0 : Sensor home position
1 : Center of work clamp
2 : Upper-left corner of work clamp
3 : Lower-left corner of work clamp
4 : Upper-right corner of work clamp
5 : Lower-right corner of work clamp
6 : Sewing start point, 7 : Sewing end point
8 : Upper-left corner of sewing pattern
9 : Lower-left corner of sewing pattern
10 : Upper-right corner of sewing pattern
11 : Lower-right corner of sewing pattern
memo-3A
1 - 3
-
2
Changes the speed limit for the given sewing pitch when the
maximum speed remains constant.
1 : Speed limit is increased for the given sewing pitch and the
sewing speed for that pitch is increased.
2 : Standard
3 : Speed limit is decreased for the given sewing pitch and the
sewing speed for that pitch is decreased.
Note
If sewing slippage occurs in places where a large sewing pitch is
used, reduce the setting to 3.
Furthermore, sewing slippage may occur in some cases if setting
1 is used.
memo-3b
-
-
0
-
memo-3c
-
-
0
-
memo-3d
-
-
0
-
memo-3E
-
-
0
-
memo-3F
-
-
0