Brother International DCP 8080DN Service Manual - Page 465
<WSW25>, Selectors 1 and 2: External TAD no-tone detection start delay time
UPC - 012502622697
View all Brother International DCP 8080DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 465 highlights
Selector No. Function Setting and Specifications No. 1 2 1 2 External TAD no-tone detection start delay time 0 0: 0 sec. 0 1: 8 sec. 1 0: 16 sec. 1 1: 24 sec. No. 3 4 3 4 External TAD no-tone detection level 0 0: -43 dB (A) 0 1: -46 dB (B) 1 0: -49 dB (C) 1 1: -51 dB (D) No. 5 6 7 0 0 0: 2 sec. 0 0 1: 4 sec. 5 0 1 0: 6 sec. I Pause between paging number and PIN (Not used.) 0 1 1: 8 sec. 7 1 0 0: 10 sec. 1 0 1: 12 sec. 1 1 0: 14 sec. 1 1 1: 16 sec. 8 Not used. Note: • Selectors 5 through 7 are applicable to the U.S.A. models only. • Selectors 1 and 2: External TAD no-tone detection start delay time Valid only for the external TAD mode. This machine will delay the start of detection for no tone by the length of time set by selectors 1 and 2. The sum of the detection delay time setting and the waiting time for no-tone detection setting by selectors 1 through 5 of WSW21 must be within 40 seconds or less. • Selectors 3 and 4: External TAD no-tone detection level These selectors set the no-tone detection level in the external TAD mode. App. 1-31 Confidential