Brother International GT-361 Basic Instruction Manual - English - Page 21
Under the Platen, Platen Fixing Lever
View all Brother International GT-361 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
2-6. Under the Platen 2. Identifying Your Printer's Parts 0049Y No. Name 1 Platen Fixing Lever Description Fixes the Platen. Tighten/Loosen this lever to install/uninstall the Platen and to adjust the Platen height. 2 Platen Height Adjustment Lever 3 Bush Platen Shaft Move the Platen Height Adjustment Lever (2) to the A position in the right image and loose the Platen Fixing Lever (1). When you pull out the Lever (1), you can turn it with no load so that move the Lever (1) to easy-to-operate position. Then tighten the Lever (1) to fix the Platen. Adjusts the Platen height. Left most position "A" is the normal T-shirt position. Check the exact height with Platen Button on Control Panel when you print on thicker material. The adequate clearance between the Flap Sensor and the printed material is app. 2 mm. See "4-5. Placing the T-shirt on the Platen" in the Instruction Manual. Ink mist may spreads inside the printer If you print with wider clearance, the ink mist will spread inside the printer and the printing material, and may damage the sensors. Fixes and holds the Platen. 4 Platen Positioning Plate You can use Lower-the-Platen Assy (option) when you regularly print thicker material, which can lower the platen by 13 mm than the standard height. See "4-4-3. Lowering the Platen height" in the Instruction Manual. GT-3 Series 12