Fig. 3.19, Fig. 3.20
View all Brother International HL1060 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Note: Follow instructions below when installing the cleaner ASSY HR. • Put the cleaner ASSY HR on the heat roller. • Rotate the hook of the cleaner ASSY HR as shown in the figure to fit it into the fixing unit frame. • Insert the cleaner lock into the fixing unit frame. Cleaner ASSY HR , , PutthecleanerASSYHRon the heat roller and rotate it in this direction to fit it into the hole. Heatroller , , Fixingunitframe Cleaner lock Fig. 3.19 (13) Remove the bind B tight 3 x 10 screw securing the connector plate. (14) Remove the connector plate from the fixing unit frame and loosen the other bind B tight 3 x 10 screw securing the fixing unit cover. (15) After removing the idle gear 16 from the fixing unit frame, the heat roller can be removed. You can then remove the halogen heater lamp from the heat roller. Note: Never touch the surface of the halogen heater lamp. Heat roller Halogen heater lamp (Blue 100V, Red 200V) Bind B tight M3x10 Bind B tight M3x10 Idle gear 16 Connector plate Fig. 3.20 III-13 Fixing unit frame