Brother International RH-9800 Instruction Manual - English - Page 34

Knife operation BEFORE/OFF/AFTER setting, ON: Enabled Determined by timer

Page 34 highlights

6. USING THE OPERATION PANEL AND FRONT PANEL No. Contents Setting range 07 Y direction offset for return seam to prevent OFF: No offset thread breakage ON: Offset by 1/2 pitch 08 Sewing end pitch for buttonhole taper to OFF: No change prevent fraying ON: Change No. of stitches before pitch change for memory 09 switch No. 08 01: 1 stitch, 02: 2 stitches, 03: 3 stitches, * Does not appear when memory switch No. 08 04: 4 stitches, 05: 5 stitches is set to OFF. 10 No. of stitches after pitch change for memory switch No. 08 * Does not appear when memory switch No. 08 is set to OFF. 01: 1 stitch, 02: 2 stitches, 03: 3 stitches, 04: 4 stitches, 05: 5 stitches, 06: 6 stitches, 07: 7 stitches, 08: 8 stitches, 09: 9 stitches 11 Test feeding speed OFF: Standard speed ON: Low speed Speed for memory switch No. 11 20: 20% of standard speed 12 * Does not appear when memory switch No. 11 35: 35% of standard speed is set to OFF. 50: 50% of standard speed 13 Knife operation (BEFORE/OFF/AFTER) setting OFF: Setting not possible within cycle program ON: Setting possible within cycle program 14 Special lapel cutting device OFF: Disabled ON: Enabled 15 Button hole sensor (Special lapel cutting OFF: Disabled device) ON: Enabled Timer for checking lowering of cutting block OFF:Disabled (Determined from slit signal 16 (Timer for determining if cutting block is stopping) lowered) ON: Enabled (Determined by timer) 17 Time for memory switch No. 16 * Does not appear when memory switch No. 16 is set to OFF. 42: 420 ms, 45: 450ms, 48: 480ms, 51: 510ms, 54: 540 ms 18 Changing cutting block ON time * Disabled (always "OFF") when switch No. 16 is "ON" memory OFF: Disabled (25 ms) ON: Enabled 19 Time for memory switch No. 18 * Does not appear when memory switch No. 18 is set to OFF. 05: 50 ms, 10: 100ms, 15: 150ms, 20: 200 ms 20 Timer for checking raising of cutting block (Timer for determining if the cutting block has been raised to a position where it will not touch the next feed bracket to operate) OFF: Disabled (Determined from number of slit signals) ON: Enabled (Determined by timer) Time for memory switch No. 20 15: 150ms, 20: 200 ms, 25: 250ms, 21 * Does not appear when memory switch No. 20 30: 300ms, 35: 350ms, 40: 400ms, is set to OFF. 45: 450ms, 50: 500ms Cutting block raising check timer (Raised position of the cutting block is 22 determined from the number of slit signals, and OFF: Disabled timer is updated) ON: Enabled * Disabled (always "OFF") when memory switch No. 20 is "ON" Time for memory switch No. 22 05: 50 ms, 10: 100ms, 15: 150ms, 23 * Does not appear when memory switch No. 22 20: 200 ms, 25: 250ms, 30: 300ms, is set to OFF. 35: 350ms, 40: 400ms 24 Setting tacking length to 0 for straight tacking OFF: Disabled specifications ON: Enabled 25 Spare - 99 Initial value OFF OFF 01 01 OFF 50 OFF OFF OFF OFF 45 OFF 05 OFF 20 OFF 05 OFF - RH-9800 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

6. USING THE OPERATION PANEL AND FRONT PANEL
RH-9800
28
No.
Contents
Setting range
Initial
value
07
Y direction offset for return seam to prevent
thread breakage
OFF: No offset
ON: Offset by 1/2 pitch
OFF
08
Sewing end pitch for buttonhole taper to
prevent fraying
OFF: No change
ON: Change
OFF
09
No. of stitches before pitch change for memory
switch No. 08
* Does not appear when memory switch No. 08
is set to OFF.
01: 1 stitch, 02: 2 stitches, 03: 3 stitches,
04: 4 stitches, 05: 5 stitches
01
10
No. of stitches after pitch change for memory
switch No. 08
* Does not appear when memory switch No. 08
is set to OFF.
01: 1 stitch, 02: 2 stitches, 03: 3 stitches,
04: 4 stitches, 05: 5 stitches, 06: 6 stitches,
07: 7 stitches, 08: 8 stitches, 09: 9 stitches
01
11
Test feeding speed
OFF: Standard speed
ON: Low speed
OFF
12
Speed for memory switch No. 11
* Does not appear when memory switch No. 11
is set to OFF.
20: 20% of standard speed
35: 35% of standard speed
50: 50% of standard speed
50
13
Knife operation (BEFORE/OFF/AFTER) setting
OFF: Setting not possible within cycle program
ON: Setting possible within cycle program
OFF
14
Special lapel cutting device
OFF: Disabled
ON: Enabled
OFF
15
Button hole sensor (Special lapel cutting
device)
OFF: Disabled
ON: Enabled
OFF
16
Timer for checking lowering of cutting block
(Timer for determining if cutting block is
lowered)
OFF:Disabled
(Determined
from
slit
signal
stopping)
ON: Enabled (Determined by timer)
OFF
17
Time for memory switch No. 16
* Does not appear when memory switch No. 16
is set to OFF.
42: 420 ms, 45: 450ms, 48: 480ms,
51: 510ms, 54: 540 ms
45
18
Changing cutting block ON time
* Disabled (always "OFF") when memory
switch No. 16 is "ON"
OFF: Disabled (25 ms)
ON: Enabled
OFF
19
Time for memory switch No. 18
* Does not appear when memory switch No. 18
is set to OFF.
05: 50 ms, 10: 100ms,
15: 150ms, 20: 200 ms
05
20
Timer for checking raising of cutting block
(Timer for determining if the cutting block has
been raised to a position where it will not touch
the next feed bracket to operate)
OFF: Disabled (Determined from number of slit
signals)
ON: Enabled (Determined by timer)
OFF
21
Time for memory switch No. 20
* Does not appear when memory switch No. 20
is set to OFF.
15: 150ms, 20: 200 ms, 25: 250ms,
30: 300ms, 35: 350ms, 40: 400ms,
45: 450ms, 50: 500ms
20
22
Cutting block raising check timer
(Raised position of the cutting block is
determined from the number of slit signals, and
timer is updated)
* Disabled (always "OFF") when memory
switch No. 20 is "ON"
OFF: Disabled
ON: Enabled
OFF
23
Time for memory switch No. 22
* Does not appear when memory switch No. 22
is set to OFF.
05: 50 ms, 10: 100ms, 15: 150ms,
20: 200 ms, 25: 250ms, 30: 300ms,
35: 350ms, 40: 400ms
05
24
Setting tacking length to 0 for straight tacking
specifications
OFF: Disabled
ON: Enabled
OFF
25
99
Spare
-
-