Brother International RH-981A Instruction Manual - English - Page 20

Parameter Changing of the Program No. 5 - 01

Page 20 highlights

Chapter 3 EXAMPLE OF THE PROGRAM CHANGE PROCEDURE Parameter Changing of the Program No. 5 Described below is a series of operations for parameter changing. Procedures below exemplify how to change settings as follows by reading program No. 5 and how to write the changed data to the machine. • Changing the numerals of parameter 01 (eyelet pattern) from [2] to [4]. • Changing the numerals of parameter 02 (button hole length) from [30] to [28]. • Changing the numerals of parameter 19 (taper tack angle) from [0] to [1]. At first, read program No. [05] from the machine. 1. Set program No. of the machine to [05] and press the [P] key. The program No.5 is automatically read. Then proceed to step 6. When the auto read/write setting is OFF, continue to perform step 2 through step 5. At the time of shipping, the auto read/write setting is set to be ON. 2. Press the [MENU] key to display the menu screen. 3. Select the icon and press the [ENTER] key. W0013Q 4. Select [YES] with the [ ] key and press the [ENTER] key. The data is read from the machine. 1577Q 5. Confirm PGNO. is set to 05 and press the [ENTER] key. W0040Q (NOTE) The parameter screen can also be displayed with the [SHORT CUT] key. E-14 PD-9810

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65

E-14
PD-9810
Chapter 3
EXAMPLE OF THE PROGRAM CHANGE PROCEDURE
Parameter Changing of the Program No. 5
Described below is a series of operations for parameter changing.
Procedures below exemplify how to change settings as follows by reading program No. 5 and how to
write the changed data to the machine.
Changing the numerals of parameter 01 (eyelet pattern) from [2] to [4].
Changing the numerals of parameter 02 (button hole length) from [30] to [28].
Changing the numerals of parameter 19 (taper tack angle) from [0] to [1].
At first, read program No. [05] from the machine.
1.
Set program No. of the machine to [05] and press the [P] key.
The program No.5 is automatically read. Then proceed to step 6. When the auto read/write setting is
OFF, continue to perform step 2 through step 5. At the time of shipping, the auto read/write setting is
set to be ON.
2.
Press the [MENU] key to display the menu screen.
3.
Select the <Machine read> icon and press the [ENTER] key.
4.
Select [YES] with the [
] key and press the [ENTER] key.
The data is read from the machine.
5.
Confirm PGNO. is set to 05 and press the [ENTER] key.
(NOTE)
The parameter screen can also be displayed with the [SHORT CUT] key.
W0013Q
1577Q