Campbell Scientific CM106B CM106B Tripod - Page 24
Enclosure Mounting to Tripod Leg, CM106B Tripod, Enclosure with the -MM bracket
View all Campbell Scientific CM106B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
CM106B Tripod Install the U-bolts, flat washers, lock washers, and nuts (FIGURE 6-11). Tighten the nuts until the lock washers are compressed. Route the 14 AWG wire from the ground lug on the bottom side of the enclosure to the ground lug on the base of the tripod (FIGURE 6-8). Strip 1/2 in. of insulation from each end of the wire. Insert wire ends into the ground lugs and tighten. Lock Washers FIGURE 6-11. Enclosure with the -MM bracket 6.1.7.2 Enclosure Mounting to Tripod Leg An enclosure ordered with the -LM bracket has a bracket on each side of the enclosure, and a U-bolt bracket for securing the enclosure to a tripod leg. Attach an enclosure with the -LM mounting bracket to the tripod base as follows: Slide the keyhole notch in upper corner of the -LM bracket over the extended hook located on the tripod base as shown in FIGURE 6-12, and engage the notch in the lower corner of the -LM bracket with the enclosure tab. There are six places on the tripod base with provisions for mounting enclosures with the -LM brackets. 16