Campbell Scientific HMP60 HMP60 Temperature and Relative Humidity Probe - Page 14

Campbell Scientific HMP60 Manual

Page 14 highlights

HMP60 Temperature and Relative Humidity Probe TABLE 5-1. Recommended Lead Lengths 2 m Height Mast/Leg 9' CM202 11' CM6 11' Atop a tripod or tower via a 2 ft crossarm such as the CM202 CM10 14' CM110 14' CM115 19' CM120 24' UT10 14' UT20 24' UT30 37' Note: Add two feet to the cable length if you are mounting the enclosure on the leg base of a light-weight tripod. The probe's cable can terminate in Pigtails that connect directly to a Campbell Scientific datalogger (option -PT). Connector that attaches to a prewired enclosure (option -PW). Refer to www.campbellsci.com/prewired-enclosures for more information. Connector that attaches to a CWS900 Wireless Sensor Interface (option -CWS). The CWS900 allows the probe to be used in a wireless sensor network. Refer to www.campbellsci.com/cws900 for more information. Connector that attaches to a CS110 Electric Field Meter or an ETseries weather station (option -C). Refer to www.campbellsci.com/cs110-sensor for more information. • 6. Specifications Features Field -replaceable humidity chip eliminates recalibration down time Compatible with all Campbell Scientific dataloggers (including the CR200(X) series) Compatible with the CWS900-series interfaces, allowing it to be used in a wireless sensor network CR200(X) series CR800 series CR1000 CR3000 CR5000 CR9000(X) CR7X CR510 CR10(X) CR23X 21X -40° to +60°C 7.1 cm (2.8 in) Compatibility Dataloggers: Operating Temperature: Probe Length: 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

HMP60 Temperature and Relative Humidity Probe
TABLE 5-1.
Recommended Lead Lengths
2 m Height
Atop a tripod or tower via a 2 ft crossarm such as the CM202
Mast/Leg
CM202
CM6
CM10
CM110
CM115
CM120
UT10
UT20
UT30
9'
11'
11'
14'
14'
19'
24'
14'
24'
37'
Note:
Add two feet to the cable length if you are mounting the enclosure on the leg base of a light-weight tripod.
The probe’s cable can terminate in:
Pigtails that connect directly to a Campbell Scientific datalogger
(option –PT).
Connector that attaches to a prewired enclosure (option –PW). Refer
to
www.campbellsci.com/prewired-enclosures
for more information.
Connector that attaches to a CWS900 Wireless Sensor Interface
(option –CWS). The CWS900 allows the probe to be used in a
wireless sensor network. Refer to
www.campbellsci.com/cws900
for
more information.
Connector that attaches to a CS110 Electric Field Meter or an ET-
series weather station (option –C). Refer to
www.campbellsci.com/cs110-sensor
for more information.
6.
Specifications
Features:
Field -replaceable humidity chip eliminates recalibration down time
Compatible with all Campbell Scientific dataloggers (including the
CR200(X) series)
Compatible with the CWS900-series interfaces, allowing it to be used
in a wireless sensor network
Compatibility
Dataloggers:
CR200(X) series
CR800 series
CR1000
CR3000
CR5000
CR9000(X)
CR7X
CR510
CR10(X)
CR23X
21X
Operating Temperature:
-40
°
to +60
°
C
Probe Length:
7.1 cm (2.8 in)