Campbell Scientific TE525MM TE525, TE525WS, and TE525MM Texas Electronics Rain - Page 21
Appendix A. Edlog Program Examples
View all Campbell Scientific TE525MM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Appendix A. Edlog Program Examples A.1 CR10X Pulse Count Example Program The CR10X program will also work with the CR500, CR510, CR10, 21X or CR23X. CR7 programming is similar to the CR10X but has an additional parameter in the Pulse (P3) instruction to specify the slot that the pulse card is in. ;{CR10X} *Table 1 Program 01: 1.0000 Execution Interval (seconds) 1: Pulse (P3) 1: 1 2: 1 3: 2 4: 3 5: 0.254 6: 0 Reps Pulse Channel 1 Switch Closure, All Counts Loc [ Rain_mm ] Multiplier Offset 2: If time is (P92) 1: 0 2: 60 3: 10 Minutes (Seconds --) into a Interval (same units as above) Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 101 Array ID 4: Real Time (P77) 1: 1220 Year,Day,Hour/Minute (midnight = 2400) 5: Totalize (P72) 1: 1 2: 3 Reps Loc [ Rain_mm ] *Table 2 Program 01: 0 Execution Interval (seconds) *Table 3 Subroutines End Program A-1