Canon LV-7210 lv7210_series_basic_cmd.pdf - Page 21

[CR], 3.10 04 [CR], 4 Input Mode Read COMMAND, 5 Lamp Time Read COMMAND

Page 21 highlights

Basic Serial Functional Specification for LV-5210/7215/7210 7.3.9 "24" [CR] Status: Processing Power Save・Cooling Down Cooling down by the power management function in the e setting menu. The control command is invalid. This Power Save・Cooling Down moves to Power Save after the cooling down time. Status: No signal POWER SAVE Response: "00" POWER SAVE ・ COOLING DOWN "24" "04" After 5 minutes with no signal after about 90 seconds 7.3.10 "04" [CR] Status of Power Save The status is Power Save by the Power management function in setting menu. 7.4 Input Mode Read COMMAND COMMAND "CR1" [CR] Detail Get selected Input No. Acceptable "%1" [CR] Response "1" = Computer1 is selected %1 "2" = Computer2 is selected "3" = Video is selected. Unacceptable "?" [CR] 7.5 Lamp Time Read COMMAND COMMAND "CR3" [CR] Detail Get total lamp running hours. Acceptable "%1" [CR] Response %1 Show as 4 digits Ex.: "0410"[CR 410 hours Unacceptable "?" [CR] Page 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

Basic Serial Functional Specification for LV-5210/7215/7210
7.3.9
“24” [CR]
Status:
Processing Power Save
Cooling Down
Cooling down by the power management function in the e setting menu.
The control command is invalid.
This Power Save
Cooling Down moves to Power Save after the cooling down time.
Status:
No signal
POWER
SAVE
COOLING
DOWN
POWER SAVE
Response:
”00”
“24”
“04”
After 5 minutes with no signal
after about 90 seconds
7.3.10 “04” [CR]
Status of Power Save
The status is Power Save by the Power management function in setting menu.
7.4 Input Mode Read COMMAND
COMMAND
“CR1” [CR]
Detail
Get selected Input No.
Acceptable
1” [CR]
1
“1” = Computer1 is selected
“2” = Computer2 is selected
“3” = Video is selected.
Response
Unacceptable
“?” [CR]
7.5 Lamp Time Read COMMAND
COMMAND
“CR3” [CR]
Detail
Get total lamp running hours.
Acceptable
1” [CR]
1
Show as 4 digits
Ex.: “0410”[CR]
・・・・
410 hours
Response
Unacceptable
“?” [CR]
Page