CR_PTIMERCOMMAND, 12.5 CR_TEMPWARNCOMMAND, Ex. When S_W_S[CR] means that sensor 1 is safety

Page 47 highlights

EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210 9.12.4 CR_PTIMERCOMMAND COMMAND "CR_PTIMER" [CR] Details Get Presentation Timer status Acceptable "000_%a" [CR] Response "ON"------- Presentation timer is active %a "STOP"--- Presentation timer is pause "OFF"----- Presentation timer is inactive Unacceptable "?" [CR] 9.12.5 CR_TEMPWARNCOMMAND COMMAND "CR_TEMPWARN" [CR] Details Get if the sensors are exceeding or approaching critical temperature. When some sensors are installed inside the projector, get each sensor's temperature. Acceptable "000_%a_%b_%c" [CR] Response %a...temperature sensor 1 status %b...temperature sensor 2 status %c...temperature sensor 3 status "W"--- Exceeding critical temperature(Warning) "S"--- Sensor temperature is safe. %a "N"--- Not relate to the temperature %b Ex. When "S_W_S"[CR] means that sensor 1 is safety %c temperature, sensor 2 is exceeding critical temperature, and sensor 3 is safety temperature. Note)Depends on projector Models, when the temperature difference between sensor 1 and sensor 2 is over the specified temperature, the sensor may show "W". In this case, sensor 3 shows that the temperature difference is "W", "S", or "N". Unacceptable "?" [CR] 9.12.6 CR_TEMPFAILCOMMAND COMMAND "CR_TEMPFAIL" [CR] Details Get the temperature inside a projector. When some temperature sensors are installed in the projector, it is possible to know the temperature all at once. Acceptable "000_%a_%b_%c" [CR] Response %a=Temperature, sensor 1 %b=Temperature, sensor 2 %c=Temperature, sensor 3 (Ex.) "_31.5F" [CR] _means a space. When the temperature sinks to -, the first %a %b %c character "-"like "-05.5F" [CR]. Last character indicates the sensor's status. Exceeding critical temperature ="F" Sensor temperature is safe ="S" Not relate to the temperature="N" "_31.5F"indicates 31.5 degrees and safety temperature. When the temperature is safe, the data will be " 00.0S". Every time the projector is reset, " 00.0S"is set. In short, previous data is deleted. Unacceptable "?" [CR] Page 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION
for LV-5210/7215/7210
Page
47
9.12.4 CR_PTIMERCOMMAND
COMMAND
“CR_PTIMER” [CR]
Details
Get Presentation Timer status
Acceptable
“000_%a” [CR]
%a
“ON”------- Presentation timer is active
“STOP”--- Presentation timer is pause
“OFF”----- Presentation timer is inactive
Response
Unacceptable
“?” [CR]
9.12.5 CR_TEMPWARNCOMMAND
COMMAND
“CR_TEMPWARN” [CR]
Details
Get if the sensors are exceeding or approaching critical temperature.
When
some sensors are installed inside the projector, get each sensor’s
temperature.
Acceptable
“000_%a_%b_%c” [CR]
%a
%b
%c
%a…temperature sensor 1 status
%b…temperature sensor 2 status
%c…temperature sensor 3 status
“W”--- Exceeding critical temperature
Warning
“S”--- Sensor temperature is safe.
“N”--- Not relate to the temperature
Ex. When “S_W_S”[CR] means that sensor 1 is safety
temperature, sensor 2 is exceeding critical temperature,
and sensor 3 is safety temperature.
Note
Depends on projector Models, when the temperature
difference between sensor 1 and sensor 2 is over the specified
temperature, the sensor may show “W”.
In this case, sensor
3 shows that the temperature difference is “W”, “S”, or “N”.
Response
Unacceptable
“?” [CR]
9.12.6 CR_TEMPFAILCOMMAND
COMMAND
“CR_TEMPFAIL” [CR]
Details
Get the temperature inside a projector.
When some temperature sensors are installed in the projector, it is possible
to know the temperature all at once.
Acceptable
“000_%a_%b_%c” [CR]
%a
%b
%c
%a
Temperature, sensor 1
%b
Temperature, sensor 2
%c
Temperature, sensor 3
(Ex.) “_31.5
” [CR]
_means a space.
When the temperature sinks to -, the first
character “-”like “-05.5F” [CR].
Last character indicates the sensor’s status.
Exceeding critical temperature
”F”
Sensor temperature is safe
”S”
Not relate to the temperature
”N”
“_31.5F”indicates 31.5 degrees and safety temperature.
When the temperature is safe, the data will be “
00.0S”.
Every time the projector is reset, “
00.0S”is set.
In short, previous data is deleted.
Response
Unacceptable