LV-7575 Basic Serial Command Functional Specifications 7 Status Read Command 7.1 Format PC issues a command in the following format. "CR" Command [CR] Command: one character (See Status Read Command Table) When projector receives an appropriate command, it returns the required data in string. Required Data [CR] Required Data: string (See Status Read Command Table) When the received data cannot be decoded, the projector returns "?" [CR] is returned. 7.2 Transfer Example Geting Input mode information of projector by Basic Commands. PC Projector Projector PC Command (issue current input mode command) "C" "R" "1" CR "1" CR Response (A few ms 5 s) (Indicating Computer 1 is selected) 7.3 Status Read Command Command "CR0" [CR] Detail Get the projector's operating status Acceptable "%1" [CR] "00" = Power ON "80" = Standby "40" = Countdown in process "20" = Cooling Down in process "10" = Power Failure Response %1 "28" = Cooling Down in process due to Abnormal Temperature "88" = Standby after Cooling Down due to Abnormal Temperature "24" = Power-Save Cooling Down in process "04" = Power Save "21" = Cooling Down in process after OFF due to Lamp Failure "81" = Standby after Cooling Down due to Lamp Failure Unacceptable "?" [CR] Details for Response "00" [CR] Status: Power ON Normal image is on-screen. 22/26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

LV-7575 Basic Serial Command Functional Specifications
22/26
7
Status Read Command
7.1 Format
PC issues a command in the following format.
“CR” Command [CR]
Command: one character (See Status Read Command Table)
When projector receives an appropriate command, it returns the required data in string.
Required Data [CR]
Required Data: string (See Status Read Command Table)
When the received data cannot be decoded, the projector returns
“?”
[CR]
is returned.
7.2 Transfer Example
Geting Input mode information of projector by Basic Commands.
Command (issue current input mode command)
PC
Projector
“C”
“R”
“1”
CR
Projector
PC
“1”
CR
←―――→
Response
(A few
ms
5 s
)
(Indicating Computer 1
is selected)
7.3 Status Read Command
Command
“CR0” [CR]
Detail
Get the projector’s operating status
Acceptable
“%1” [CR]
%1
”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Abnormal Temperature
“88” = Standby after Cooling Down due to Abnormal Temperature
“24” = Power-Save Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after OFF due to Lamp Failure
“81” = Standby after Cooling Down due to Lamp Failure
Response
Unacceptable
“?” [CR]
Details for Response
“00” [CR]
Status: Power ON
Normal image is on-screen.