Canon LV-7575 LV-7575 Basic Serial Command Functional Specifications - Page 25

Input Mode Read Command, 5 Lamp Time Read Command, 6 Setting Read Command, 7 Temp Read Command

Page 25 highlights

LV-7575 Basic Serial Command Functional Specifications 7.4 Input Mode Read Command Command "CR1" [CR] Detail Get currently selected Input No. Acceptable "%1" [CR] "1" = Input 1 is selected. Response %1 "2" = Input 2 is selected. "3" = Input 3 is selected. "4" = Input 4 is selected.(only for Networking-capable models) Unacceptable "?" [CR] 7.5 Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours. *return lamp operating time multiplied by the given coefficient (not actual used time) Acceptable "%1" [CR] Display Lamp running hours with 5 digit numbers. Response %1 Example: "00410" [CR 410 hours Unacceptable "?" [CR] 7.6 Setting Read Command Command "CR4" [CR] Detail Get screen setting status such as Ceiling/Rear. Acceptable "%1" [CR] "11" [CR] = Normal Screen Setting "10" [CR] = Picture is top/bottom reversed. (Status: Rear & Ceiling Response %1 ON) "01" [CR] = Picture is left/right reversed. (Status: Rear ON) "00" [CR] = Picture is top/bottom and left/right reversed. (Status: Ceiling ON) Unacceptable "?" [CR] 7.7 Temp Read Command Command "CR6" [CR] Detail Get the information of temperature inside a projector. With several built-in temperature sensors, it can get all the temperatures at once. Acceptable "%1 _ %2 _ %3" [CR] %1 = Temp. of sensor 1 %2 = Temp. of sensor 2 %3 = Temp. of sensor 3 Temperature data basic format is "_00.0". ("_" indicates a space) When the temperature goes under 0, it starts with "-" instead of a %1 space like "-05.5" [CR]. Response %2 When no temperature data returns due to hardware problems, it %3 starts with "E" like"E00.0" [CR]. With several built-in temperature sensors, the projector returns the values in succession. "_31.5_ _35.2_ 33.4 " [CR] The first sensor's data is followed by one space and afterwards the second sensor's data. Unacceptable "?" [CR] 25/26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

LV-7575 Basic Serial Command Functional Specifications
25/26
7.4 Input Mode Read Command
Command
“CR1” [CR]
Detail
Get currently selected Input No.
Acceptable
“%1” [CR]
%1
”1” = Input 1 is selected.
“2” = Input 2 is selected.
“3” = Input 3 is selected.
“4” = Input 4 is selected.(only for Networking-capable models)
Response
Unacceptable
“?” [CR]
7.5 Lamp Time Read Command
Command
“CR3” [CR]
Detail
Get total lamp running hours.
*return lamp operating time multiplied by the given coefficient (not actual used
time)
Acceptable
“%1” [CR]
%1
Display Lamp running hours with 5 digit numbers.
Example:
“00410” [CR] ---------- 410 hours
Response
Unacceptable
“?” [CR]
7.6 Setting Read Command
Command
“CR4” [CR]
Detail
Get screen setting status such as Ceiling/Rear.
Acceptable
“%1” [CR]
%1
“11” [CR] = Normal Screen Setting
“10” [CR] = Picture is top/bottom reversed. (Status: Rear & Ceiling
ON)
“01” [CR] = Picture is left/right reversed. (Status: Rear ON)
“00” [CR] = Picture is top/bottom and left/right reversed. (Status:
Ceiling ON
)
Response
Unacceptable
“?” [CR]
7.7 Temp Read Command
Command
“CR6” [CR]
Detail
Get the information of temperature inside a projector.
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable
“%1 _ %2 _ %3” [CR]
%1
%2
%3
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is “_00.0”. (“_” indicates a space)
When the temperature goes under 0, it starts with “-” instead of a
space like “-05.5” [CR].
When no temperature data returns due to hardware problems, it
starts with “E” like”E00.0” [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
“_31.5_ _35.2_ 33.4 ” [CR]
The first sensor’s data is followed by one space and afterwards
the second sensor’s data.
Response
Unacceptable
“?” [CR]