Lamp Use Warning Starting Time long type Unit: second

Page 6 highlights

009. SOUND MUTE OFF Function: This command cancels the sound muting. Command: 02H 13H 00H 00H 00H 15H Response (ACK): At the time of a success 22H 13H 01H xxH 00H CKS (*2) Response (NAK): At the time of a failure A2H 13H 01H xxH 02H DATA01 DATA02 CKS (*2) Data portion Description DATA01 Error type DATA02 Error description For more information, see "5. Data Portion of Response." 010. ONSCREEN MUTE ON Function: This command mutes the on-screen display. Command: 02H 14H 00H 00H 00H 16H Response (ACK): At the time of a success 22H 14H 01H xxH 00H CKS (*2) Response (NAK): At the time of a failure A2H 14H 01H xxH 02H DATA01 DATA02 CKS (*2) Data portion Description DATA01 Error type DATA02 Error description For more information, see "5. Data Portion of Response." Supplement: * This is available only during on-screen display. 011. LAMP INFORMATION REQUEST Function: This command acquires the lamp information of projector. Command: 03H 8CH 00H 00H 00H 8FH Response (ACK): At the time of a success 23H 8CH 01H xxH 10H DATA01 to DATA16 CKS (*2) Data Portion Contents DATA01 to 04 Lamp counter (long type Unit: second) DATA05 to 08 Lamp counter in Quiet mode (long type Unit: second) DATA09 to 12 Lamp Use Warning Starting Time (long type Unit: second) DATA13 to 16 Lamp Use Prohibited Time (long type Unit: second Response (NAK): At the time of a failure A3H 8CH 01H xxH 02H DATA01 DATA02 CKS (6)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

009. SOUND MUTE OFF
**********************************************************************
Function:
This command cancels the sound muting.
Command:
02H
13H
00H
00H
00H
15H
Response (ACK): At the time of a success
22H
13H
01H
xxH
00H
CKS
(*2)
Response (NAK): At the time of a failure
A2H
13H
01H
xxH
02H
DATA01
DATA02
CKS
(*2)
Data portion
Description
-----------------------------------------------------------------------
DATA01
Error type
DATA02
Error description
For more information, see "5. Data Portion of Response."
010. ONSCREEN MUTE ON
**********************************************************************
Function:
This command mutes the on-screen display.
Command:
02H
14H
00H
00H
00H
16H
Response (ACK): At the time of a success
22H
14H
01H
xxH
00H
CKS
(*2)
Response (NAK): At the time of a failure
A2H
14H
01H
xxH
02H
DATA01
DATA02
CKS
(*2)
Data portion
Description
-----------------------------------------------------------------------
DATA01
Error type
DATA02
Error description
For more information, see "5. Data Portion of Response."
Supplement:
* This is available only during on-screen display.
011. LAMP INFORMATION REQUEST
**********************************************************************
Function:
This command acquires the lamp information of projector.
Command:
03H
8CH
00H
00H
00H
8FH
Response (ACK): At the time of a success
23H
8CH
01H
xxH
10H
DATA01 to DATA16
CKS
(*2)
Data Portion
Contents
-------------------------------------------------------------------
DATA01 to 04
Lamp counter
(long type Unit: second)
DATA05 to 08
Lamp counter in Quiet mode (long type Unit: second)
DATA09 to 12
Lamp Use Warning Starting Time (long type Unit: second)
DATA13 to 16
Lamp Use Prohibited Time (long type Unit: second
Response (NAK): At the time of a failure
A3H
8CH
01H
xxH
02H
DATA01
DATA02
CKS
(6)