Canon LV-X6 LV2005_2006_com_list.pdf - Page 7
Data01 To Data05 - lamp
View all Canon LV-X6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
(*2) Data portion Description DATA01 Error type DATA02 Error description For more information, see "5. Data Portion of Response." Supplement: Example of lamp timer acquisition DATA01 DATA02 DATA03 DATA04 : Timer in Normal mode 30H 2AH 00H 00H : 10800 seconds 012. MUTE CONTROL Function: This command controls the mute of picture, sound and on-screen. Command: 02H 1AH 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents DATA01 Mute type to be controlled 00H : Picture 01H : Sound 02H : OSD (DATA2 can be specified only for "On") DATA02 Mute Control 00H : Off 01H : On Response (ACK): At the time of a success 22H 1AH 01H xxH 01H DATA01 CKS (*2) Data Portion Contents DATA01 Results 00H : Normal 01H : Error Response (NAK): At the time of a failure A2H 1AH 01H xxH 02H DATA01 DATA02 CKS (*2) Data portion Description DATA01 Error type DATA02 Error description For more information, see "5. Data Portion of Response." Supplement: * Mute is cancelled in the following cases: Input connector switching Video signal switching Volume adjustment 013. VOLUME ADJUST Function: This command sets the volume. Command: 03H 10H 00H 00H 05H DATA01 to DATA05 CKS Data Portion Contents (7)