Canon PowerShot G11 Professional Products 2010 Brochure - Page 24
Nomenclature for EOS 50D
View all Canon PowerShot G11 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Nomenclature for EOS 50D Hot Shoe LCD Panel Illumination Button Metering Mode Selection/White Balance Selector Button AF Mode Selection/Drive Mode Selection Button ISO Speed/Flash Exposure Compensation Button Main Dial Shutter Button Red-Eye Reduction/ Self-Timer Lamp Grip Battery Compartment Cover and Release Lever Viewfinder Eyepiece Live View Shooting/Print/Share Button MENU Button LCD Monitor Picture Style Selection Button Erase Button Playback Button Info/Trimming Orientation Button Function Button Top LCD Panel Information Shutter Speed ( ) Busy ( ) Built-in Flash Recycling ( ) Flash Exposure Compensation White Balance Auto Daylight Shade Cloudy Tungsten Light White Fluorescent Light Flash Custom Color Temperature Exposure Level Indicator • Exposure Compensation Amount • AEB Level • Flash Compensation Amount Image Recording Quality Battery Check Highlight Tone Priority 159 Beeper AF Point Selection ( CF Card Full Warning ( CF Card Error Warning ( No CF Card Warning ( Error Code ( Cleaning Image Sensor ( ) ) ) ) ) ) Aperture Setting ( ) Shots Remaining ( ) Shots Remaining During WB-BKT ( ) Self-Timer Countdown ( ) Bulb Exposure Time ( ) WB Correction/ WB-BKT White Balance AF Mode Drive Mode Single Low-Speed Continuous High-Speed Continuous Self-Timer (10 sec.) Self-Timer (2sec.) AEB Metering Mode Evaluative Partial Spot Center-Weighted Average ISO Speed ( ) Monochrome Shooting Built-in Flash/AF-Assist Beam Flash-Sync Contacts Flash Button Mode Dial Strap Mount Remote Control Terminal (N3 Type) Lens Release Button DIGITAL Terminal VIDEO OUT Terminal HDMI Terminal Depth-of-Field Preview Button Tripod Socket Dioptric Adjustment Knob AF Start button AE Lock/FE Lock Button/Index/Reduce Button AF Point Selection/Magnify Button Multi-Controller SET Button CF Card Slot Cover Quick Control Dial Access Lamp Viewfinder Information AF Point Power Switch Spot Metering Circle Focusing Screen * AE Lock AEB in-progress Flash-Ready/ Improper FE Lock Warning High-Speed Sync Indicator (FP Flash) (* - FE Lock) Flash Exposure Compensation CF Card Full Warning ( ) CF Card Error Warning ( ) No CF Card Warning ( ) Shutter Speed ( ) FE Lock ( ) Busy ( ) Built-in Flash Recycling ( ) Focus Confirmation Light • During One-Shot Autofocus: Lights when focus is achieved, blinks at 2Hz if focus fails • During Manual Focus: Lights when focus is achieved Maximum Burst ( ) White Balance Correction/ Monochrome Shooting ISO Speed Highlight Tone Priority Exposure Level • Exposure Compensation Amount • AEB Level • Red-Eye Reduction Lamp On Aperture Value ( ) EOS-1Ds Mark III Custom Function Chart Custom Function Function Description C.Fn I: Exposure 1 Exposure level increments 2 ISO speed setting increments 3 Set ISO speed range 4 Bracketing Auto Cancel 5 Bracketing sequence 6 Number of bracketing shots 7 Spot metering link to AF point 8 Safety Shift 9 Select usable shooting modes Select usable 10 metering modes No. Setting 0 1/3-stop increments 1 Speeds/apertures 1-stop increments, Exposure compensation in 1/3-stops 2 1/2-stop increments 0 ISO set in 1/3-stop increments 1 ISO set in 1-stop increments Disable (camera ISO range 100~3200) Enable (apply user-registered available ISO range) - Set highest ISO (1-stop increments) up to "H" Register Set lowest ISO (1-stop increments), "L" thru 1600 Return 0 On (AEB cancels if camera turned off, etc.) 1 Off (AEB remains in effect unless flash turned on) 00 -+ 1- 0+ 2+ 0- 0 3 shots 1 2 shots 2 5 shots 3 7 shots 0 Disable (spot metering always at center) 1 Enable (spot metering at manually selected AF pt.) 0 Disable 1 Enable (Tv/Av modes) 2 Enable (ISO speed shifts, in P, Tv, Av modes) Disable (all exposure modes available) Enable (only modes registered are selectable) - M P Register Tv BULB Av Apply Disable (all metering patterns available) Enable (only metering modes registered are selectable) - Register Apply 11 Metering pattern in Manual mode 12 Set shutter speed range 13 Set aperture value range Apply shooting/ 14 Metering mode 1B5 Flash sync. speed in ) Av mode ) C.Fn BII: Image/Flash exp/Display Lo)ng exp. noise 1 reduction Fla 2 ComHipgheISnOssapeteidon noise reduction 3 Highlight tone priority 4 E-TTL II flash metering 5 Shutter curtain sync. 6 Flash firing F 7 LigVihewtfinder info. during exp. 8 LCD panel illumination during Bulb 9 TeIsNmhFoOoptbienugrttaontuwhreen C.Fn III: Autofocus/Drive 1 USM lens electronic MF 2 AI Servo tracking sensitivity 3 AI Servo 1st/2nd image priority 4 AI Servo AF tracking method 5 Lens drive when AF impossible Lens AF stop button function 6 (select Canon Super-telephoto IS lenses only) 0 Specified metering mode on camera's LCD panel 1 Evaluative metering only in M mode 2 Partial metering only in M mode 3 Spot metering only in M mode 4 Center-weighted average only in M mode Disable Enable (apply user-registered range) - Highest speed: 250-8000 Register Lowest speed: 30"-60 Apply Disable (use lens's full aperture range) Enable (apply user-registered aperture range) - Min. aperture (Max. f/): 1.4-91 Register Max. aperture ((Min. f/): 1.0-64 Apply Disable (no switching to registered settings) Enable (Press " * " button to switch settings) - With AE lock button (AF on) Register With AE lock button (AF off) 0 Auto (shutter speed set based on ambient light) 1 1/250 sec. 0 Off 1 Auto (camera decides whether to apply reduction) 2 On (noise reduction applied; 1 sec. and longer only) 0 Off A 1 On 0 Disable 1 Enable 0 Evaluative flash metering 1 Average flash metering over all 63 metering zones 0 1st-curtain synchronization 1 2nd-curtain synchronization (EOS Speedlites only) 0 Enable 1 Disable - AF assist beam continues to operate 0 Disable 1 Enable (viewfinder info visible during bursts) 0 Off 1 On during Bulb 0 LCD monitor Displays camera settings 1 LCD monitor Displays shooting functions 0 MF possible after One-shot AF completed 1 Disable after One-shot AF 2 Disable completely in AF mode - Slow: -2, -1, 0, +1, +2: Fast 0 AF priority/2nd shot onward - Tracking priority 1 AF priority/2nd shot onward - Drive speed priority 2 Release/2nd shot onward - Drive speed priority 0 Main focus point priority 1 Continuous AF track priority (ignores closer objects) 0 Focus search on 1 Focus search off 0 AF stop 1 AF start 2 AE lock Custom Function Function Description 6 (Cont.) 7 AF Microadjustment AF expansion with 8 selected pt 9 Selectable AF point 10 Switch to registered AF point 11 AF point auto selection 12 AF point display during focus 13 AF point brightness 14 AF-assist beam firing 15 Mirror lockup 16 Continuous shooting speed 17 Limit continuous shot count C.Fn IV: Operation/Others Shutter button/ 1 AF-ON button 2 AF-ON/AE lock button switch Quick Control Dial in 3 meter 4 SET button when shooting 5 Tv/Av setting for Manual exp. 6 Dial direction during Tv/Av 7 Av setting without lens 8 WB + media/image size setting 9 Button function Button function when 10 11 Focusing screen 12 Timer length for timer 13 Shortened release time lag 14 Add aspect ratio information 15 S Add original decision data 16 Live View Function exposure simulation No. Setting 3 AF point:M Auto/Auto ctr 4 ONE SHOT AI Servo 5 IS start 6 Switch to registered AF point 0 Disable (no adjustment for front or back-focus) 1 Adjust all by same amount 2 Adjust by lens Forward: -20 ........ 0 ....... +20 Backward 0 Disable (one AF point only when manually selected) 1 Enable (expand by adding left/right Assist pts) 2 Enable (expand by adding ring of six surrounding Assist pts) 0 19 points 1 Inner 9 points 2 Outer 9 points 0 Disable 1 Enable 0 direct: disable / : enable 1 direct: disable / :disable (auto AF select mode impossible to access) 2 direct: enable / : enable 0 On (red illumination on) 1 Off 2 On (lights momentarily when focus achieved) 0 Normal 1 Brighter 0 Enable (Speedlite's AF assist beam fires normally) 1 Disable 0 Disable 1 Enable (mirror lowers after each shot) 2 Enable: Down with SET (mirror remains up until SET pressed) Disable (shoots at default fps rates) Enable (applies user-registered fps rates) - High speed: 5,4,3,2 fps Register Low speed: 1,2,3,4 fps Apply Disable Enable - Register Limited shots: 99-2 Apply 0 Metering + AF start (at both buttons) 1 Metering + AF start/AF stop 2 Metering start/Meter + AF start (no AF at shutter button) 3 AE lock/Metering + AF start 4 Metering + AF start/disable (AF-on button) 0 Disable 1 Enable (reverse role of AEL and AF-on buttons) 0 Exposure comp/Aperture 1 AF point selection (instant AF point access with rear dial) 2 ISO speed (instant ISO access with rear dial) 0 Normal (disabled) 1 White balance 2 Image size 3 ISO Speed 4 Picture Style 5 Record func. + media/folder 6 Menu display 7 Image playback 0 Tv= / Av= 1 Tv= / Av= (reverse functions in M mode for top/rear dials) 0 Normal 1 Reserve direction 0 Disable 1 Enable (possible to set aperture on body w/o lens) 0 Rear LCD panel 1 LCD monitor (displayed when FUNC button pressed) 0 Protect (hold button in: sound rec.) 1 Sound rec. (press & release; protect possible via menu only) 0 Normal (enable) 1 Disable , , Multi-controller 0 Ec-C IV 1 Ec-A, B, C, C II, C III, D, H, I, L 2 Ec-S 3 Ec-N, R Disable (use camera's built-in settings) Enable (apply user-registered changes) - Register 6 sec. timer: 0-6-59 sec., 1-60 min. 16 sec. timer: 0-16-59 sec., 1-60 min. Time after release: 0-2-59 sec., 1-60 min. Apply 0 Disable (standard 55ms "time lag") 1 Enable (as low as 40ms, depending upon lens aperture) 0 Off 1 Aspect ratio 6:6 2 Aspect ratio 3:4 3 Aspect ratio 4:5 4 Aspect ratio 6:7 5 Aspect ratio 10:12 6 Aspect ratio 5:7 E 0 Off 1 On (used by optional Original Data Security Kit) 0 Disable (LCD auto adjust) 1 Enable (LCD simulates actual exposure level) 160