Canon imageFORMULA DR-G2140 User Manual - Page 48
Set [Feeding Option] on the [Feeding] tab to [Manual
View all Canon imageFORMULA DR-G2140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
IMPORTANT When [Scanning Side] is set to [Folio], [Detect by Ultrasonic] in the [Error Detection] tab sheet - [Double Feed Detection] is automatically turned off. 3 Set [Feeding Option] on the [Feeding] tab to [Manual Feeding]. (See p. 44) IMPORTANT A portion of the scanned image will be missing at the fold line. 6 Place the document with the folded edge facing right. Fʢroදnʣt Bʢaཪcʣk 4 Click the [OK] button to close the settings screen. 5 Fold the document in half. Crease the document firmly down its center to fold the document in half. Fold the document so that its edges are neatly aligned. If the document is not folded properly, paper jams may occur or distortions may appear in the combined scanned image. Reconsʢtr߹uctըe૾d ʣImage IMPORTANT Adjust the document guides to fit the width of the document. Otherwise, the image may scan as skewed or shifted. Hint • The scanned image of the front side becomes the left half of the recombined image. • The maximum size for combined images is A2. Use this method to scan A2-sized documents. When scanning a folded document of a size other than the standard formats, set [Page Size] on the scanner driver settings screen to [Match original size]. (See p. 80) 48