Clifford IntelliGuard 950 Owners Guide - Page 26
user selectable features
View all Clifford IntelliGuard 950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
note: Refer to the Feature Descriptions sections of this guide for important notes and descriptions of the system features and programming. 7. Exit programming - To exit programming mode turn the ignition off or wait 60 seconds without pressing the PlainView 2 Valet switch. The siren will chirp three times to indicate programming mode has been exited. user selectable features First Press Then Press Add new remote (autolearn)*** Change PIN code New remote learn arm/disarm only Auto (passive) arm on/off Not used New remote learn accessory A channel Chirps on/off/quiet Not used New remote learn accessory B channel Auto lock ignition/off/rpm Remote valet on/off New remote learn silent mode Auto unlock ignition/off Entry delay on/off New remote learn remote valet Auto (passive) arm and lock on/off Reset all features to factory (except remotes and PIN code) New remote learn remote start* Not used Not used New remote learn window down/vent** Second unlock on/off Autostart setting* (off/battery only/ New remote learn temp only/ accessory C channel battery and temp) Not used BlackJax on/off**** Clear all remotes * This feature is only available with optional IntelliStart connected. ** This feature is only available with optional SmartWindows connected. *** 5-button Radar 2 only. To program 4-button remote use New remote learn in column 3. **** This feature is not evaluated by Thatcham. © 2004 directed electronics, inc. 23