Operation Operating Limits OIntrpo eratiOnpegratioLnimitsCAsussitsotmanecre Warranty • Power Output The inverter can deliver 1000 watts for about 60 minutes. TrehseuimnveeorIntpestearrllamatitoiunosnt cool for at 1000 15 minutes wattsN. oNtesote: before it can The wattage rating Secondary Icons applies to resistive loads. The inverter will operate most AC loads within its power rating. Some induction motors used in freezers, pumps, and other motor-operated equipment require very high surge currents to start. The inverter may not be able to start somNoeticeof thesCeaumtioon tors evWeanrninthg ough their rated current draw is within the inverter's limits. The inverter will normally start single phase induction motors rated at one-half HP or less. Input Voltage The inverter will operate from input voltage ranging from 10 volts to 15 volts. Optimum performance will occur when the voltage is between 12 volts and 14 volts. If the voltage drops below 11.3V +/- 0.3V, an audible low battery warning will sound. The inverter will shut down if the input voltage drops below 10.3V +/- 0.3V. This protects the battery from being over-discharged. It will restart when the input voltage exceeds 12V +/-0.3V. The inverter will also shut down if the input voltage exceeds 15.5V+/-0.5V. This protects the inverter against excessive input voltage. Although the inverter has protection against over-voltage, it may still be damaged if the input voltage were to exceed 16 volts. 18 Operation Troubleshooting Guide TIntrrooubleOspehratoionotingACsuGssitsotumaneicrde e Warranty • Problem/Symptom Possible Causes Solution Low output voltage Overload Reduce the load. No outpuIntstvalolaltitoange Secondary Icons Low input Notes voltage Recharge battery. Check connections and cable. No output voltage Thermal after prolonged use shutdown Allow inverter to cool off. Reduce load, Notice Caution Warning continuous operation input current required. Improve ventilation; Make sure ventilation openings in the inverter are not obstructed. Reduce ambient temperature. No output voltage, High input "Protect" indicator voltage lighted Make sure the inverter is connected to 12V battery. Check regulation of charging system. No output voltage Short circuit Check load for proper operation. No output voltage Inverter switched off Turn inverter on. No power to inverter Check wiring to inverter. Reverse DC polarity Observe correct polarity. Low battery alarm Poor DC wiring on all the time Poor battery condition Check connections. Make sure battery is fully charged. Nothing Comes Close to a Cobra™ 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

18
19
Nothing
Comes Close to a Cobra
Troubleshooting Guide
Operation
Operating Limits
Power Output
The inverter can deliver 1000 watts for about 60 minutes.
The inverter must cool for 15 minutes before it can
resume operation at 1000 watts. Note: The wattage
rating applies to resistive loads.
The inverter will operate most AC loads within its power
rating. Some induction motors used in freezers, pumps,
and other motor-operated equipment require very high
surge currents to start. The inverter may not be able
to start some of these motors even though their rated
current draw is within the inverter’s limits. The inverter
will normally start single phase induction motors rated
at one-half HP or less.
Input Voltage
The inverter will operate from input voltage ranging
from 10 volts to 15 volts. Optimum performance will
occur when the voltage is between 12 volts and 14 volts.
If the voltage drops below 11.3V+/-0.3V, an audible low
battery warning will sound. The inverter will shut down if
the input voltage drops below 10.3V+/-0.3V. This protects
the battery from being over-discharged. It will restart when
the input voltage exceeds 12V+/-0.3V.
The inverter will also shut down if the input voltage
exceeds 15.5V+/-0.5V. This protects the inverter
against excessive input voltage. Although the inverter
has protection against over-voltage, it may still be
damaged if the input voltage were to exceed 16 volts.
Operating Limits
Operation
Problem/Symptom
Low output voltage
No output voltage
No output voltage
after prolonged use
No output voltage,
“Protect” indicator
lighted
No output voltage
No output voltage
Low battery alarm
on all the time
Possible Causes
Overload
Low input
voltage
Thermal
shutdown
High input
voltage
Short circuit
Inverter
switched
off
No power
to inverter
Reverse
DC polarity
Poor DC wiring
Poor battery
condition
Solution
Reduce the load.
Recharge battery.
Check connections
and cable.
Allow inverter
to cool off.
Reduce load,
continuous
operation input
current required.
Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.
Reduce ambient
temperature.
Make sure
the inverter is
connected to
12V battery.
Check regulation
of charging system.
Check load for
proper operation.
Turn inverter
on
.
Check wiring
to inverter.
Observe
correct polarity.
Check connections.
Make sure battery
is fully charged.
Troubleshooting Guide