Compaq AP500 Reference Guide - Page 125

XX000Y ZZ Parity, Single-bit ECC during POST.

Page 125 highlights

D-6 POST Error Messages POST Error Messages and Codes Continued Error Code Probable Source of Problem 1793-Secondary Controller or Disk Failure An error has been detected with the CD-ROM interface. A Critical Error Occurred Prior to this Power-Up Critical failure (POST) recorded into the wellness log. A Collectable Memory Error Occurred Prior to this Power-Up Single-bit ECC during POST. This Workstation has experienced an NMI (Hardware Error) As indicated. Fixed Disk Parameter Table or BIOS Error System Halted Configuration or hardware failure. XX000Y ZZ Parity Check 2 Parity RAM failure. Audible (beep) Power-on successful. Invalid Electronic Serial Number The electronic serial number is corrupt. (RESUME= "F1" KEY) As indicated to continue. Action Run the Diagnostics utility. None. None. None. Run the Setup and Diagnostics utilities. Run the Setup and Diagnostics utilities. None. Run the Setup and Diagnostics utilities. Press the F1 key.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

D-6
POST Error Messages
POST Error Messages and Codes
Continued
Error Code
Probable Source
of Problem
Action
1793-Secondary
Controller or Disk
Failure
An error has been detected with
the CD-ROM interface.
Run the Diagnostics
utility.
A Critical Error
Occurred Prior to this
Power-Up
Critical failure (POST) recorded
into the wellness log.
None.
A Collectable
Memory Error
Occurred Prior to this
Power-Up
Single-bit ECC during POST.
None.
This Workstation has
experienced an NMI
(Hardware Error)
As indicated.
None.
Fixed Disk
Parameter Table or
BIOS Error System
Halted
Configuration or hardware failure.
Run the Setup and
Diagnostics utilities.
XX000Y ZZ Parity
Check 2
Parity RAM failure.
Run the Setup and
Diagnostics utilities.
Audible (beep)
Power-on successful.
None.
Invalid Electronic
Serial Number
The electronic serial number is
corrupt.
Run the Setup and
Diagnostics utilities.
(RESUME=
"F1" KEY)
As indicated to continue.
Press the F1 key.