Compaq ML350 Compaq ProLiant ML350 Generation 2 Server Setup and Installation - Page 122

Table D-4, Problems After Initial Startup, Problem, Possible Cause, Possible Solution

Page 122 highlights

Troubleshooting D-9 Problem System cannot load SmartStart. Table D-4 Problems After Initial Startup Possible Cause Wrong version of SmartStart is being installed. The CD-ROM/diskette drive assembly is not set as a bootable device. The CD-ROM/diskette drive assembly is either not installed, or is not properly connected. Diskette in CD-ROM/diskette drive assembly is preventing the system from loading. Possible Solution 1. Check the SmartStart release notes and user documentation. 2. Refer to the Compaq website to verify the version of SmartStart 1. Press the F9 key to run the ROM Based Setup Utility (RBSU) when prompted. 2. Set defaults and exit the utility. 3. Rerun RBSU to verify the system configuration. Refer to Chapter 5, "Server Configuration and Utilities," or the Compaq ROM Based Setup Utility User Guide on your server documentation CD for complete instructions on the use of RBSU. 1. Power down the server. 2. Verify that the CD-ROM/diskette drive assembly is installed. 3. Remove and reseat the CD-ROM/diskette drive assembly. 4. Check the cable between the backplane and the CD-ROM/diskette drive assembly to ensure proper connection. Refer to the Compaq ProLiant ML350 Generation 2 Server Maintenance and Service Guide for connection information. If the cable is not the problem, refer to "CD-ROM Problems" in the Compaq Servers Troubleshooting Guide. Remove the diskette. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

Troubleshooting
D-9
Table D-4
Problems After Initial Startup
Problem
Possible Cause
Possible Solution
System
cannot load
SmartStart.
Wrong version of
SmartStart is being
installed.
1.
Check the SmartStart release notes and user
documentation.
2.
Refer to the Compaq website to verify the version of
SmartStart
The CD-ROM/diskette
drive assembly is not set
as a bootable device.
1.
Press the
F9
key to run the ROM Based Setup Utility
(RBSU) when prompted.
2.
Set defaults and exit the utility.
3.
Rerun RBSU to verify the system configuration.
Refer to Chapter 5,
Server Configuration and Utilities,
or
the
Compaq ROM Based Setup Utility User Guide
on your
server documentation CD for complete instructions on the
use of RBSU.
The CD-ROM/diskette
drive assembly is either
not installed, or is not
properly connected.
1.
Power down the server.
2.
Verify that the CD-ROM/diskette drive assembly is
installed.
3.
Remove and reseat the CD-ROM/diskette drive
assembly.
4.
Check the cable between the backplane and the
CD-ROM/diskette drive assembly to ensure proper
connection.
Refer to the
Compaq ProLiant ML350 Generation 2
Server Maintenance and Service Guide
for connection
information.
If the cable is not the problem, refer to
CD-ROM
Problems
in the
Compaq Servers Troubleshooting
Guide
.
Diskette in
CD-ROM/diskette drive
assembly is preventing
the system from loading.
Remove the diskette.
continued