Compaq ProLiant 6400R ProLiant Server Troubleshooting Guide - Page 211
XC-31, Power Module PPM
View all Compaq ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 211 highlights
POST Error Messages Table C-9: 800 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 802-Processor X is missing or terminator board is not present. System Halted. None The system detected that the indicated processor slot is empty. 803-Processor speeds must match for system operation. System Halted None Two processors with different speed ratings are installed in the system. All installed processors must have the same speed rating for safe operation. Action 1. Be sure that a processor or processor terminator board is installed in each processor slot. 2. Reseat the processor or processor terminator board in each processor slot. 3. Be sure that each processor has a corresponding Processor Power Module (PPM) installed. 4. Try replacing each processor with a processor terminator board to detect a failed processor or PPM. 1. Replace one of the processors with a processor terminator board. 2. Replace one of the processors with an alternate processor rated for the same operating speed as the installed processor. continued HP Servers Troubleshooting Guide C-31