Compaq ProLiant 6400R ProLiant Server Troubleshooting Guide - Page 246
Array SCSI Drives, Recovery Mode will
View all Compaq ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 246 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1789-Slot X Drive Array SCSI Drive(s) Not Responding. Check cables or replace the following SCSI drives: SCSI Port Y: SCSI ID Z None Drives that were working when the system was last used are now missing or are not starting up. Possible drive problem or loose SCSI cable. Select F1 to continue - drive array will remain disabled. Select F2 to failed drives that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. Action 1. Power down the system, check cable connections, and be sure that all drives are fully seated in their drive bays. 2. Power cycle any external SCSI enclosures while the system is off. 3. Power on the server to see if problem still exists. 4. If configured for faulttolerant operation and the RAID level can sustain failure of all indicated drive(s), press the F2 key to fail the drive(s) that are not responding and replace with good drive(s) immediately. 5. Otherwise, press the F1 key to start the system with all logical drives on the controller disabled. Be sure that system is always powered up and down correctly. • When powering up the system, all external storage systems must be turned on before server. • When powering down the system, the server must be powered down before external storage systems. continued C-66 HP Servers Troubleshooting Guide