Compaq ProLiant 800 HP ProLiant BL e-Class Integrated Administrator User Guide - Page 98
Table 4-6, Server Bay Management Commands, HDD | RBSU]}
View all Compaq ProLiant 800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Command Line Interface Table 4-6: Server Bay Management Commands continued Command Description GENERATE NMI Generates an NMI on the specified blade. The consequences of an NMI are operating system specific. POWEROFF BAY } {FORCE} Performs a graceful shutdown of the server blade in the specified bay. If the FORCE argument is given, the server blade is immediately shut down. This means the server blade could lose data or become unstable. If no server blade is in the specified bay, the user is told that the bay is empty. POWERON BAY } {[PXE | HDD | RBSU]} Powers on the specified server blade. If no server blade is in the specified bay, the user is told that the bay is empty. The optional boot arguments require a BIOS version of 06/15/02 or greater of the ProLiant BL10e Server blade ROM. Adding an optional boot argument forces the blade to abandon the regular boot order and forces a boot using the specified method. Restrictions Only enclosure and group administrators may execute this command. Only enclosure and group administrators may execute this command. Only enclosure and group administrators may execute this command. continued HP ProLiant BL e-Class Integrated Administrator User Guide 4-21