Power Over Ethernet, Denied Counter, Absent Counter, Invalid Signature Counter: 0
UPC - 790069296567
View all D-Link DES-3010PA-TAA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 199 highlights
Power Over Ethernet Denied Counter Absent Counter Invalid Signature Counter: 0 The following table describes the fields shown in the display: Field Power Nominal Power Consumed Power Usage Threshold Traps Port Powered device Admin State Priority Oper State Classification Overload Counter Short Counter Denied Counter Absent Counter Invalid Signature Counter Description The inline power sourcing equipment operational status. The inline power sourcing equipment nominal power in Watts. Measured usage power in Watts. The usage threshold expressed in a percentage for comparing the measured power and initiating an alarm if the threshold is exceeded. Indicates if inline power traps are enabled. The Ethernet port number. A description of the powered device type. Indicates if the port is enabled to provide power. It can be Auto or Never. The priority of the port from the point of view of inline power management. It can be Critical, High or Low. Describes the inline power operational state of the port. It can be On, Off, TestFail, Testing, Searching or Fault. Power consumption classification of the powered device. Counts the number of overload conditions that has been detected. Counts the number of short conditions that has been detected. Counts the number of times power has been denied. Counts the number of times power has been removed because powered device dropout was detected. Counts the number of times an invalid signature of a powered device was detected. Page 198