D-Link DFE-2616X User Guide - Page 52
Master Hub Setup and Management
UPC - 790069212604
View all D-Link DFE-2616X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Dual-Speed Stackable Hubs User's Guide The figure above shows an unsegmented hub stack. All hubs in the stack are in the same collision domain because they are connected together through the daisy-chain ports. The figure below shows a stack divided into three separate collision domains. Hubs three and four are isolated from the main segment (collision domain one) using the hub's segmentation capability, putting them into their own isolated collision domains two and three respectively. A switch, bridge or router can be used to connect the three collision domains so that traffic can pass between them, yet keeping them isolated to reduce congestion on each segment. 40 Master Hub Setup and Management
Dual-Speed Stackable Hubs User’s Guide
Master Hub Setup and Management
40
The figure above shows an unsegmented hub stack.
All hubs in the stack are
in the same collision domain because they are connected together through the
daisy-chain ports.
The figure below shows a stack divided into three separate collision domains.
Hubs three and
four are isolated from the main segment (collision domain
one) using the hub's segmentation capability, putting them into their own
isolated collision domains two and three respectively.
A switch, bridge or
router can be used to connect the three collision domains so that traffic can
pass between them, yet keeping them isolated to reduce congestion on each
segment.