D-Link DFE-2616X User Guide - Page 70
Group Slot 1, Group Slot 2, Group Isolate
UPC - 790069212604
View all D-Link DFE-2616X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
Dual-Speed Stackable Hubs User's Guide hh:mm:ss.xx, with hh representing hours since the master hub was turned on, mm the minutes, ss the seconds, and xx representing 100ths of a second. ♦ Group Slot (1). Shows the status of module slot 1. If there is a module installed in slot 1, this field will display: MII, TP, FX, or Switch as determined by the type of module installed. If there is no module installed, the field will display one." ♦ Group Slot (2). Shows the status of module slot 2. If there is a module installed in slot 2, this field will display: MII, TP, FX, or Switch as determined by the type of module installed. If there is no module installed, the field will display one." ♦ Group Isolate. Provides control of the hub current network connection status and allows the system manager to manually isolate a particular hub as needed and reconnect it later. Toggling the field to solate" separates the hub data connection from the other hubs. Toggling the field to econnect" re-establishes the connection. See egmenting Hubs" earlier in this chapter for more information. DFE-2600 Stackable Hub - Network Monitoring : Group Configuration Menu Group ID (1-5) [1] Group Serial Number: Group Position Number: Group Description: Group Role: Group Port Capacity: Group Hardware Revision: Group Master Revision: Group Status: Group Last Oper Change: Group Slot (1): Group Slot (2): 623000B DFE2624i Primary Master 24 Rev. 06 Rev. 01 Up 0:1:35.90 Switch none Group Isolate: PREV GROUP NEXT GROUP HELP SAVE EXIT 58 Master Hub Setup and Management