D-Link DFE-550FX Adapter Network Operation Test 4. If you have access to a second station on the LAN, then skip ahead to Step 5. If you do not have access to a second station on the LAN, then the network test will be limited to blind transmission of test packets (none of which will be returned to the primary station). Follow the cues at the foot of the screen to select and run the Network Diagnostic program. Observe the Packets Sent line to see a steadily and rapidly increasing packet count. This will indicate normal transmission onto the LAN, and will be the end of your Verification/Diagnostic run. Skip the remaining steps shown below. 5. Remove the DFE-550FX Software Diskette from your station's (the primary station's) diskette drive, and insert it into an available drive of a second station on your LAN. At the DOS prompt (here shown as >), key in: > A:\DIAG.EXE and . The opening screen of the Diagnostic program will appear onscreen at the second station. Follow the cues at the foot of the screen to select and run the Network Test program at the second station. The second station then begins broadcasting test packets, and at the same time is also ready to receive and return test signals transmitted from the primary station newly installed DFE-550FX. 6. Return to the primary station and follow the cues at the foot of the screen to select and run the Network Diagnostic program. Observe the Packets Sent and Packets Received lines to see that they track together (always showing equal count numbers), which verifies normal network operation. The most likely causes of failure for any of the diagnostic tests are incorrect options settings, option settings that conflict with the settings of other boards or improper installation. In the event of any failure in diagnostic tests, refer to the Troubleshooting section of this guide. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

D-Link DFE-550FX Adapter
8
Network Operation Test
4.
If you have access to a second station on the LAN, then skip
ahead to Step 5.
If you do not have access to a second station
on the LAN, then the network test will be limited to blind
transmission of test packets (none of which will be returned to
the primary station).
Follow the cues at the foot of the screen
to select and run the Network Diagnostic program.
Observe the
Packets Sent
line to see a steadily and rapidly increasing packet
count.
This will indicate normal transmission onto the LAN,
and will be the end of your Verification/Diagnostic run.
Skip
the remaining steps shown below.
5.
Remove the DFE-550FX Software Diskette from your station's
(the primary station's) diskette drive, and insert it into an
available drive of a second station on your LAN.
At the DOS
prompt (here shown as
>
), key in:
> A:\DIAG.EXE
and
<RETURN>
.
The opening screen of the Diagnostic program
will appear onscreen at the second station.
Follow the cues at
the foot of the screen to select and run the Network Test
program at the second station.
The second station then begins
broadcasting test packets, and at the same time is also ready to
receive and return test signals transmitted from the primary
station newly installed DFE-550FX.
6.
Return to the primary station and follow the cues at the foot of
the screen to select and run the Network Diagnostic program.
Observe the
Packets Sent
and
Packets Received
lines to see that
they track together (always showing equal count numbers),
which verifies normal network operation.
The most likely causes of failure for any of the diagnostic tests are
incorrect options settings, option settings that conflict with the
settings of other boards or improper installation.
In the event of
any failure in diagnostic tests, refer to the
Troubleshooting
section
of this guide.