Dacor DRT304 Installation Instructions - Page 13

Verifying Proper Operation - distinctive

Page 13 highlights

Installation Instructions Verifying Proper Operation warning • Make sure that power to the electrical outlet is turned off at the circuit breaker or fuse box and that the gas is turned off at the gas supply valve before proceeding. • The cooktop must be properly grounded at all times when electrical power is applied. Prior to operating the cooktop, read the accompanying use and care manual carefully. 1. Make sure all the cooktop burner con- trols are in the OFF position. 2. Connect the power OFF cord to the electrical outlet. HIGH LOW 3. Turn on power to the electrical outlet at the circuit breaker or fuse box. 4. Gently push in and turn one burner control knob at a time counterclockwise to the HIGH position. Verify that the associated burner igniter sparks, then return the knob to the OFF position. Repeat for all of the remaining control knobs. 5. Turn on the gas supply valve. 6. Perform the following ignition test for all of the burners: • Push in and turn one of the control knobs counterclockwise to the HIGH position. Only the igniter for the selected burner will spark. It may take up to four seconds for the gas to ignite, at which time the igniter will stop sparking. If ignition does not occur within four seconds, turn the knob to the OFF position, wait for at least five minutes to allow any gas to dissipate, then repeat the test. • Once the burner lights, the control knob can be rotated counterclockwise from HIGH to LOW to adjust the flame height progressively. • When the unit is installed properly, the flame will be steady. It will also have a sharp, blue inner cone that will vary in length proportional to the burner size. The flame will be reduced by the Smart Flame™ feature under the grate fingers to increase grate life. Normal Flame Appearance NOTE: If the cooktop does not operate properly, follow these troubleshooting steps: • Verify that power and gas are supplied to the cooktop. • Check to make sure that the power plug is connected to the electrical outlet and that power is turned on at the circuit breaker or fuse box. • Check to make sure that all burner parts are properly seated. • If the burner continues to spark after ignition without stopping, have a licensed electrician check the electrical outlet for proper grounding or reversed polarity. • Repeat the burner ignition test. If the appliance still does not work, contact Dacor Distinctive Service at (877) 337-3226. Do not attempt to repair the appliance yourself. Be sure to have the model and serial numbers available when you call. See the inside cover for location. Dacor is not responsible for the cost of correcting problems caused by a faulty installation. Installation Checklist warning To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. Proper installation is the responsibility of the homeowner. The importance of proper installation of your Dacor cooktop cannot be overemphasized. □□ Is the electrical outlet for the cooktop grounded and located according to these instructions and in accordance with all applicable electrical codes? See pages 3 and 4. □□ Is the gas service for the cooktop located and installed according to these instructions and in accordance with all applicable codes? See pages 3 and 4. □□ Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums stated in these instructions? See page 3. □□ Is the cooktop secured using the provided hold-down bolts and washers? See page 8. □□ Is the cooktop connected to the gas supply according to these instructions and in accordance with all applicable codes? Did the installer check the gas supply for leaks? See page 9. □□ Are all burner parts and grates properly installed according to these instructions? See page 10. □□ Has proper operation been verified? □□ Has the warranty been activated on-line or the warranty card filled out completely and mailed? 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

11
Verifying Proper Operation
WARNING
Make sure that power to the electrical outlet is turned
off at the circuit breaker or fuse box and that the gas
is turned off at the gas supply valve before proceed-
ing.
The cooktop must be properly grounded at all times
when electrical power is applied.
Prior to operating the cooktop, read the accompanying use
and care manual carefully.
1.
Make sure all the
cooktop burner con-
trols are in the
OFF
position.
2. Connect the power
cord to the electrical outlet.
3.
Turn on power to the electrical outlet at the circuit
breaker or fuse box.
4.
Gently push in and turn one burner control knob at a
time counterclockwise to the
HIGH
position. Verify that
the associated burner igniter sparks, then return the
knob to the
OFF
position. Repeat for all of the remain-
ing control knobs.
5.
Turn on the gas supply valve.
6.
Perform the following ignition test for all of the burners:
Push in and turn one of the control knobs counter-
clockwise to the
HIGH
position. Only the igniter for
the selected burner will spark. It may take up to four
seconds for the gas to ignite, at which time the ignit-
er will stop sparking. If ignition does not occur within
four seconds, turn the knob to the
OFF
position, wait
for at least five minutes to allow any gas to dissipate,
then repeat the test.
Once the burner lights, the control knob can be rotat-
ed counterclockwise from
HIGH
to
LOW
to adjust the
flame height progressively.
When the unit is
installed properly, the
flame will be steady. It
will also have a sharp,
blue inner cone that
will vary in length pro-
portional to the burner
size. The flame will be
reduced by the Smart
Flame™ feature under
the grate fingers to
increase grate life.
NOTE: If the cooktop does not operate properly, follow
these troubleshooting steps:
Verify that power and gas are supplied to the cooktop.
Check to make sure that the power plug is connected
to the electrical outlet and that power is turned on at
the circuit breaker or fuse box.
Check to make sure that all burner parts are properly
seated.
If the burner continues to spark after ignition without
stopping, have a licensed electrician check the electri-
cal outlet for proper grounding or reversed polarity.
Repeat the burner ignition test.
If the appliance still does not work, contact Dacor
Distinctive Service at (877) 337-3226. Do not attempt to
repair the appliance yourself. Be sure to have the model
and serial numbers available when you call. See the inside
cover for location. Dacor is not responsible for the cost of
correcting problems caused by a faulty installation.
Installation Checklist
WARNING
To ensure a safe and proper installation, the following
checklist should be completed by the installer to ensure
that no part of the installation has been overlooked.
Proper installation is the responsibility of the homeowner.
The importance of proper installation of your Dacor
cooktop cannot be overemphasized.
Is the electrical outlet for the cooktop grounded and
located according to these instructions and in accor-
dance with all applicable electrical codes? See pages
3 and 4.
Is the gas service for the cooktop located and installed
according to these instructions and in accordance with
all applicable codes? See pages 3 and 4.
Has the gas supply inlet pressure been measured to
ensure that it does not exceed the maximums stated in
these instructions? See page 3.
Is the cooktop secured using the provided hold-down
bolts and washers? See page 8.
Is the cooktop connected to the gas supply according
to these instructions and in accordance with all appli-
cable codes? Did the installer check the gas supply for
leaks? See page 9.
Are all burner parts and grates properly installed
according to these instructions? See page 10.
Has proper operation been verified?
Has the warranty been activated on-line or the warranty
card filled out completely and mailed?
Normal Flame
Appearance
Installation Instructions
OFF
HIGH
LOW