Dacor DRT304 Installation Instructions - Page 5
Installation Requirements - drt304s lp h
View all Dacor DRT304 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation Requirements warning • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • To prevent an electric shock hazard, the power supply must meet the specifications stated below. The electrical and gas supply data on this page is for reference only. If the requirements below do not agree with the product data label, use the data on the product data label. Electrical Requirements • The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70 and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269-9101 • The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. • The electrical outlet must be installed by a licensed electrician. ELECTRIC CIRCUIT REQUIREMENTS Circuit Required Total Connected Load 120 Vac 60 Hz., 15 Amp. (3 wire) 1.0 Amp. @ 120 Vac, 60 Hz. Gas Supply Requirements • Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. The gas service must be installed by a qualified professional • Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation. See the inside cover for more information. • An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance. • The factory provided regulator shipped with the appliance must be installed in the gas line that runs from the gas shut off valve to the cooktop gas inlet. Use only the regulator provided. The regulator inlet accommodates a 3/4" gas supply line and is also compatible with a 1/2" house gas supply. The inlet to the cooktop itself is equipped with a 3/4" male NPT fitting. GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure for all models is 1/2 p.s.i. Product Dimensions 28 1/8" (71.4 cm) 25 7/8" (65.7 cm) Trim: 1/2" (1.3 cm) thick 1 5/8" (4.1 cm) cooking surface height (grate level) above countertop 7 3/4" (19.7 cm) A COOKTOP WIDTH (A) DRT304S 29 7/8" (75.9 cm) DRT366S 35 7/8" (91.1 cm) 4" (10.2 cm) Power cord 32" (81.3 cm) long 3/4" gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2" (5.1 cm) from chassis bottom 5/8" min. (1.6 cm) SIDE VIEW Product tolerances: ±1/16" (±1.6 mm) unless otherwise noted. 3