Installation Instructions Electrical Connection (Continued) Connecting an Appliance Wire to the Range - Where Local Code Permits WARNING Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit. 1. Remove the range electrical access cover from the back of the range. 2. If using a 4 wire connection, loosen the grounding screw and remove the neutral to ground jumper link. 3. Remove the conduit bracket from the bottom of the range electrical box. 5. Slide the end of the appliance cord into the strain relief from the bottom of the box. 6. Connect the white (neutral) wire to the neutral terminal in the box. 7. Connect the L1 wire to the L1 power supply terminal in the box. 8. Connect the L2 wire to the L2 power supply terminal in the box. 9. If using a 4 wire connection, connect the ground wire to the grounding screw inside the box using a loop or spade terminal. 10. Tighten the strain relief so that the appliance cord is held snuggly in place. 11. Replace the range electrical access cover. L1 terminal Neutral terminal L2 terminal Remove jumper on 4 wire installations Remove conduit bracket before strain relief installation 4. Disassemble and remove the strain relief from the appliance cord (not included). Insert the tabs on the two parts of the strain relief into the hole on the bottom of the box and reassemble it so that the tabs are below the box and the strain relief itself is inside the box. Strain relief Jumper removed Ground screw L2 wire Green wire White wire Strain relief 4 Wire Appliance Cord Connection L2 Neutral L1 wire Bottom of range electrical box 14 Reassemble with tabs below and clamp above Ground L1 14-50P Plug

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

14
Electrical Connection (Continued)
Connecting an Appliance Wire to the
Range - Where Local Code Permits
WARNING
Do not connect the green appliance wire to the neutral (white)
supply wire unless local building codes permit.
Remove the range electrical access cover from the back of
1.
the range.
If using a 4 wire connection, loosen the grounding screw and
2.
remove the neutral to ground jumper link.
Remove the conduit bracket from the bottom of the range
3.
electrical box.
Disassemble and remove the strain relief from the appliance
4.
cord (not included). Insert the tabs on the two parts of
the strain relief into the hole on the bottom of the box and
reassemble it so that the tabs are below the box and the
strain relief itself is inside the box.
Slide the end of the appliance cord into the strain relief from
5.
the bottom of the box.
Connect the white (neutral) wire to the neutral terminal in the
6.
box.
Connect the L1 wire to the L1 power supply terminal in the
7.
box.
Connect the L2 wire to the L2 power supply terminal in the
8.
box.
If using a 4 wire connection, connect the ground wire to
9.
the grounding screw inside the box using a loop or spade
terminal.
Tighten the strain relief so that the appliance cord is held
10.
snuggly in place.
Replace the range electrical access cover.
11.
Installation Instructions
Remove jumper on
4 wire installations
Remove conduit
bracket before strain
relief installation
Strain relief
Reassemble with tabs
below and clamp above
Bottom of range
electrical box
L1 terminal
L2 terminal
L2 wire
Green wire
White wire
Strain relief
Neutral terminal
Jumper removed
Ground screw
4 Wire Appliance
Cord Connection
L2
Neutral
Ground
L1
14-50P Plug
L1 wire