Installation Specifications Cabinet Cutout Dimensions Before making the countertop cutout, make certain that the required dimensions shown below have been met or exceeded. All tolerances: +1/16, -0 (+1.6 mm, -0). unless otherwise stated. Rear wall Dimension Table Installations without Raised Vent Models A - Cooktop Cutout Width ETT304-1, MET304 28 3/4" (730 mm) ETT365-2, METB365-1 34 3/4" (883 mm) 2 1/4" Min. (57 mm) 19 3/4" Min. (502 mm) 1" Min. (25 mm) 6" (152 mm) Min. from mounting surface to combustibles below cooktop chassis A ISO view without raised vent 6" (152 mm) Min. to combustible, side wall, both sides Countertop Cutout Dimensions Without a Raised Vent Installed D B E Rear wall C 19 3/4" (502 mm) 6" Min. (152 mm) Cabinet face A Top view with raised vent 1" Min. (25 mm) 6" Min. (152 mm) 6" (152 mm) Min. from mounting surface to combustibles below cooktop chassis ISO view with raised vent Countertop Cutout Dimensions With Raised Vent Installed Dimension Table - Installations with Raised Vent Model/Configuration A - Cooktop Cutout Width ETT304-1 or MET304 cooktop with ERV30 or PRV30 raised vent. ETT304-1 or MET304 cooktop with RV30 raised vent. 28 3/4" (730 mm) B - Raised Vent Cutout Width 27 3/4" (705 mm) C - Total Cutout Depth 22 1/2" (572 mm) 22 1/4" (565 mm) ETT365-2 or METB365-1 cooktop with ERV36 or PRV36 raised vent. ETT365-2 or METB365-1 cooktop with RV36 raised vent. 34 3/4" (883 mm) 33 3/4" (857 mm) 22 1/2" (572 mm) 22 1/4" (565 mm) D - Raised Vent Cutout Depth 2 3/4" (70 mm) 2 1/2" (64 mm) 2 3/4" (70 mm) 2 1/2" (64 mm) E - Min. Rear Countertop Overhang 3/8" (10 mm) 5/8" (16 mm) 3/8" (10 mm) 5/8" (16 mm) 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

5
Cabinet Cutout Dimensions
Before making the countertop cutout, make certain that the
required dimensions shown below have been met or exceeded.
Dimension Table -
Installations without Raised Vent
Models
A - Cooktop
Cutout Width
ETT304-1, MET304
28 3/4” (730 mm)
ETT365-2, METB365-1
34 3/4” (883 mm)
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
A
Min. to combustible,
side wall, both sides
Rear
wall
1" Min.
19 3/4" Min.
(502 mm)
6" (152 mm)
(25 mm)
2 1/4" Min.
(57 mm)
6" (152 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
Rear
wall
19 3/4"
(502 mm)
6" Min.
(152 mm)
6" Min.
(152 mm)
1" Min.
(25 mm)
Cabinet
face
A
B
C
D
E
Countertop Cutout Dimensions Without a Raised Vent Installed
Countertop Cutout Dimensions With Raised Vent Installed
Installation Specifications
Dimension Table - Installations with Raised Vent
Model/Configuration
A - Cooktop
Cutout Width
B - Raised
Vent Cutout
Width
C - Total
Cutout Depth
D - Raised
Vent
Cutout Depth
E - Min. Rear
Countertop
Overhang
ETT304-1 or MET304 cooktop
with ERV30 or PRV30 raised vent.
28 3/4”
(730 mm)
27 3/4”
(705 mm)
22 1/2”
(572 mm)
2 3/4”
(70 mm)
3/8”
(10 mm)
ETT304-1 or MET304 cooktop with
RV30 raised vent.
22 1/4”
(565 mm)
2 1/2”
(64 mm)
5/8”
(16 mm)
ETT365-2 or METB365-1 cooktop
with ERV36 or PRV36 raised vent.
34 3/4”
(883 mm)
33 3/4”
(857 mm)
22 1/2”
(572 mm)
2 3/4”
(70 mm)
3/8”
(10 mm)
ETT365-2 or METB365-1 cooktop
with RV36 raised vent.
22 1/4”
(565 mm)
2 1/2”
(64 mm)
5/8”
(16 mm)
All tolerances: +1/16, -0 (+1.6 mm, -0). unless otherwise stated.