Dacor EWD24 Installation Instructions - Page 8

Install Support Platform in, Cabinet, Electrical and Environmental, Specifications

Page 8 highlights

Installation Specifications Install Support Platform in Cabinet Provide a platform (100 lb. load capacity) within the cabinet upon which the warming drawer will be supported. The platform must be installed level and straight. The top edge of the platform must be flush with the cutout at the front of the cabinet. There are no provisions to level the warming drawer after it has been installed. 3/4" (1.9 cm) thick plywood is recommended. NOTE: If the drawer is not installed in a level fashion, the drawer may slide open on its own or may not seal tightly, allowing heat to escape and resulting in poor warming drawer performance. Chassis face Support platform Electrical and Environmental Specifications warning IMPORTANT: This appliance is equipped with a three prong grounding electric plug for protection against possible electric shock hazards. It must be plugged into a dedicated, grounded, electrical outlet. If only a two prong electrical outlet is available, it is the responsibility of the customer to have it replaced with a dedicated, properly grounded three prong electrical outlet. To avoid an electric shock hazard, do not under any circumstances: • Cut or remove the third (ground) prong from the power cord. • Use an adapter plug. • Use a power cord that is frayed or damaged. • Immerse the power cord or plug in water or other liquid. • Connect the appliance to an extension cord. NOTE: Use of a ground fault interrupter (GFI) is not recommended. Three prong plug Three prong grounded outlet • Minimum ambient operating temperature: 32°F (0°C). • The correct voltage, frequency and amperage must be supplied to the electrical outlet from a grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. • The required voltage, frequency and amperage ratings are listed on the product data label. See page 1 for location. Nominal Electrical Supply Requirements 120 Vac, 60 Hz, 15 Amp., dedicated circuit The warming drawer is supplied with a 40" (101.6 cm) power cord with a three prong grounded plug. Total Connected Load 0.5 kW (4 Amp.) • The power supply requirements shown above are for reference only. If they do not agree with those listed on the product data label, use the requirements on the product data label. • It is the owner's responsibility to ensure that the electrical outlet is installed by a qualified electrician. The electrical installation must comply with the latest revision of the National Electric Code ANSI/NFPA 70 and local codes and ordinances. • If the electrical service provided does not meet the product specification, or does not conform to the NEC or local standards, do not proceed with the installation. Call a licensed electrician to correct the electrical service before proceeding. • Be certain to locate the electrical outlet in an accessible location, so that the warming drawer may be easily unplugged in the event that service becomes necessary. • Keep the electrical cord away from hot surfaces. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

6
Minimum ambient operating temperature: 32°F (0°C).
The correct voltage, frequency and amperage must be
supplied to the electrical outlet from a grounded, single
phase circuit that is protected by a properly sized circuit
breaker or time-delay fuse.
The required voltage, frequency and amperage ratings
are listed on the product data label. See page 1 for
location.
The power supply requirements shown above are for
reference only. If they do not agree with those listed
on the product data label, use the requirements on the
product data label.
It is the owner’s responsibility to ensure that the
electrical outlet is installed by a qualified electrician.
The electrical installation must comply with the latest
revision of the National Electric Code ANSI/NFPA 70
and local codes and ordinances.
If the electrical service provided does not meet the
product specification, or does not conform to the NEC
or local standards, do not proceed with the installation.
Call a licensed electrician to correct the electrical
service before proceeding.
Be certain to locate the electrical outlet in an
accessible location, so that the warming drawer may
be easily unplugged in the event that service becomes
necessary.
Keep the electrical cord away from hot surfaces.
Installation Specifications
Install Support Platform in
Cabinet
Provide a platform (100 lb. load capacity) within the cabinet
upon which the warming drawer will be supported. The
platform must be installed level and straight. The top edge
of the platform must be flush with the cutout at the front of
the cabinet. There are no provisions to level the warming
drawer after it has been installed. 3/4” (1.9 cm) thick
plywood is recommended.
NOTE:
If the drawer is not installed in a level fashion, the
drawer may slide open on its own or may not seal tightly,
allowing heat to escape and resulting in poor warming
drawer performance.
Support
platform
Chassis
face
Electrical and Environmental
Specifications
WARNING
IMPORTANT:
This appliance is equipped with a three
prong grounding electric plug for protection against
possible electric shock hazards. It must be plugged into
a dedicated, grounded, electrical outlet. If only a two
prong electrical outlet is available, it is the responsibility
of the customer to have it replaced with a dedicated,
properly grounded three prong electrical outlet.
To
avoid an electric shock hazard, do not under any
circumstances:
Cut or remove the third (ground) prong from the power
cord.
Use an adapter plug.
Use a power cord that is frayed or damaged.
Immerse the power cord or plug in water or other
liquid.
Connect the appliance to an extension cord.
NOTE:
Use of a ground fault interrupter (GFI) is not
recommended.
Nominal Electrical Supply Requirements
120 Vac, 60 Hz, 15 Amp., dedicated circuit
The warming drawer is supplied with a 40” (101.6 cm)
power cord with a three prong grounded plug.
Total Connected Load
0.5 kW (4 Amp.)
Three prong plug
Three prong
grounded outlet