Dacor HWO230 Installation Instruction - Wall Oven - Page 4

Customer Assurance Information, Electrical Specifications

Page 4 highlights

CUSTOMER ASSURANCE INFORMATION If you have questions or installation/repair/warranty issues, call: Dacor Customer Assurance Phone: 833-35-ELITE (833-353-5483) USA, Canada Mon - Fri 5:00 a.m. to 5:00 p.m. Pacific Time Website: www.dacor.com/customer-care/contact-us Product Data Label When you call for assistance, have the oven's model and serial numbers ready. These numbers are on the product-data label behind the grill above the oven chamber. On double ovens, the label is behind the upper oven's grill. View data plate through grate Model Identification Callout A B C D E F Name Model series Number of ovens Width Handle style Color/Material Voltage Description (HWO) Heritage Wall Oven 1 (single oven) or 2 (double oven) Inches (overall exterior) F: flush; P: Pro; No designator: Epicure B: Black; S: Stainless steel; W: White 208V: 208 Vac; No designator: 240 Vac ELECTRICAL SPECIFICATIONS • The owner shall ensure that a licensed electrician installs the oven's electrical supply (incl. minimum supply wire size), which must comply with the Nat'l Electric Code ANSI/NFPA 70 (latest rev.) and local codes/ordinances. Obtain a copy of this standard from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269-9101 • Correct voltage/frequency/amperage must be supplied to the oven from a dedicated, grounded, singlephase circuit protected by a properly sized circuit breaker or time-delay fuse. (For the fuse, fuse both sides of the line: L1 and L2.) Model HWO127 HWO130 Total Connected Load* 240 Vac 60 Hz, 19.0 Amp., 4.7 kW 240 Vac 60 Hz, 24.5 Amp., 6.0 kW Dedicated Circuit Requirements 240 Vac 60 Hz, 4 wire**, 30 Amp. • Preheat times and cavity temperature-recovery times increase slightly if operating a 240 Vac unit with less than a 240 Vac circuit. HWO227 240 Vac 60 Hz, 39.4 Amp., 9.5 kW 240 Vac 60 Hz, 4 wire**, 40 Amp. HWO230 240 Vac 60 Hz, 48.6 Amp., 12.0 kW 240 Vac 60 Hz, 4 wire**, 50 Amp. • The oven has electrical wiring in a flexible metal conduit. *For reference only. See the product data label (pg. 2) for exact specifications; **two 120 Vac hot (L1, L2), one neutral, one ground. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

2
View data plate
through grate
Model Identification
Callout
Name
Description
A
Model series
(HWO) Heritage Wall Oven
B
Number of ovens
1 (single oven) or 2 (double oven)
C
Width
Inches (overall exterior)
D
Handle style
F: flush; P: Pro; No designator: Epicure
E
Color/Material
B: Black; S: Stainless steel; W: White
F
Voltage
208V: 208 Vac; No designator: 240 Vac
If you have questions or installation/repair/warranty issues, call:
Dacor Customer Assurance
Phone: 833-35-ELITE (833-353-5483) USA, Canada
Mon – Fri 5:00 a.m. to 5:00 p.m. Pacific Time
Website: www.dacor.com/customer-care/contact-us
Product Data Label
When you call for assistance, have the oven’s model and serial
numbers ready. These numbers are on the product-data label
behind the grill above the oven chamber. On double ovens, the
label is behind the upper oven’s grill.
• The owner shall ensure that a licensed electrician installs the oven’s electrical supply (incl. minimum supply wire size), which must
comply with the Nat’l Electric Code ANSI/NFPA 70 (latest rev.) and local codes/ordinances.
Obtain a copy of this standard from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
• Correct voltage/frequency/amperage must be sup-
plied to the oven from a dedicated, grounded, single-
phase circuit protected by a properly sized circuit
breaker or time-delay fuse. (For the fuse, fuse both
sides of the line: L1 and L2.)
• Preheat times and cavity temperature-recovery
times increase slightly if operating a 240 Vac unit
with less than a 240 Vac circuit.
• The oven has electrical wiring in a flexible metal
conduit.
CUSTOMER ASSURANCE INFORMATION
ELECTRICAL SPECIFICATIONS
Model
Total Connected Load*
Dedicated Circuit
Requirements
HWO127
240 Vac 60 Hz, 19.0 Amp., 4.7 kW
240 Vac 60 Hz, 4 wire**, 30 Amp.
HWO130
240 Vac 60 Hz, 24.5 Amp., 6.0 kW
HWO227
240 Vac 60 Hz, 39.4 Amp., 9.5 kW
240 Vac 60 Hz, 4 wire**, 40 Amp.
HWO230
240 Vac 60 Hz, 48.6 Amp., 12.0 kW
240 Vac 60 Hz, 4 wire**, 50 Amp.
*For reference only. See the product data label (pg. 2) for exact specifications; **two 120